Service Manual for Dry Channel HDC3/HDC6 Units
RELAY BOX
Main Power
On/Off Switch
Figure 4. Relay Box
The Main Power On/Off Switch is located on
the lower right side of the Relay Box. This is a
lighted double pull single throw (DPST) switch
rated at 20 Amperes. The Relay Box houses a 24
Volt Step-Down Transformer and six Solid State
Relays (SSR).
6
MAIN FEATURES
I
CONTROL DISPLAY
DISPLAY
DISPLAY
On/O
Function Control
Button
Figure 5. Control Display
The display provides a readout of actual
temperature, set point temperature and fault
conditions.
The control board inside the Control Display
maintains the temperature of all three channels.
Each channel has an A & B zone. The control board
monitors each zone's temperature and activates a
relay to supply power to the heater for that zone.
When the ON/OFF button is pressed, the display
cycles through the temperature of each channel.
If a fault is detected, the fault code is displayed.
The displayed temperature will be the average of
the two zones associated with that channel.
HEAT ON
READY
Select