V. SHUTDOWN
1. On systems with a bypass valve, and where
sys tem pressure is to be maintained as the
reg u la tor is shut down, slowly open the by pass
valve while closing the inlet (up stream) block
valve. Fully close the inlet (upstream) block
valve. (When on bypass, the sys tem pressure
must be constantly ob served and man u al ly
regulated. Close the outlet (down stream) block
valve.
VI. MAINTENANCE
SYSTEM UN DER PRES SURE. Prior to performing
any maintenance, isolate the reg u la tor from the
system and relieve all pres sure. Failure to do so
could result in personal injury.
A. General:
1. Maintenance procedures hereinafter are
based upon removal of the regulator unit from
the pipe line where installed.
2. Owner should refer to owner's procedures for
removal, handling, cleaning and disposal of
nonreusable parts, i.e. gaskets, etc.
3. Refer to Figure 1, Model CA-1 or CA-2 for
the basic regulator. Blow-ups of options are
in clud ed with each drawing.
B. Diaphragm Replacement
To prevent damage to body, use lead jaws when
placing body in a vise. Position so that vise closes
over inlet and outlet of the body.
1. Securely install the body (1) in a vise with the
spring chamber (2) directed upwards.
SPRING UNDER COMPRESSION.
re mov ing spring chamber, relieve spring
compression by back ing out the ad just ing screw.
Failure to do so may result in flying parts that
could cause personal injury.
IOM-CA
WARNING
CAUTION
WARNING
Prior to
SECTION V
Do not walk away and leave a bypassed
reg u la tor unattended.
2. If the regulator and system are to both be
shut down, slowly close the inlet (upstream)
block valve. Close the outlet (downstream)
valve only if reg u la tor re mov al is required.
SECTION VI
2. Relax range spring (6) by loosening the
lock nut (4) and turning ad just ing screw (3)
CCW until re moved from spring cham ber (2).
NOTE: If the Option -2 handwheel is utilized,
the ad just ing screw (3) and lock nut (4) are re-
placed with a knob (18) and lock nut (4). With
the Option-22 panel mounting w/handwheel,
the ad just ing screw (3) and lock nut (4) are
replaced with a knob (18), lock nut (4) and a
panel mounting nut (19).
3. Loosen spring chamber (2) by placing wrench
on "flats" and rotating CCW.
4. Remove spring chamber (2), spring button (5)
range spring (6), and diaphragm stop (9).
5. Remove the diaphragm subassembly
con sist ing of the pressure plate nut (7), lock
wash er (8), pressure plate (10), diaphragm
(11), plug gasket (13) and plug (14). NOTE:
Refer to the quan tity of dia phragms (11)
in cor po rated per the bill of ma te ri als listing.
De pend ing on inlet pressure level, multiple
metal diaph ragms (11) may be "stacked".
8
11
13
Model's CA-1/CA-2 Diaphragm Sub as sem bly
6. Loosen pressure plate nut (7) and sep a rate all
parts (7, 8, 10, 11, 13 & 14) of the di a phragm
sub as sem bly.
7. Inspect pressure plate (10) to ensure no
de for ma tion due to over-pressurization. If
de formed, re place.
CAUTION
7
10
14
3