Dungs DGAI. 69F Podręcznik - Strona 4

Przeglądaj online lub pobierz pdf Podręcznik dla Kominek wewnętrzny Dungs DGAI. 69F. Dungs DGAI. 69F 4 stron. Automatic gas burner control for gas burners without fan, with intermittent ignition burner and exhaust gas monitoring

Dimensions

46,5
Heat request
signal
AW
4,2Ø

DGAI. 69F Connector table

Function
Slot
no.
Supply line/power supply
LPG-pre-valve
Gas pressure switch
111
Fault/unlock
Fault/operation
Exhaust gas sensor
162
Ignition
Gas valve 1
Gas valve 2
Ionisation
1)
IPCD terminal 3623... / Screw terminal 3611...
We reserve the right to make any changes in the interest of technical progress.
Automatic gas burner control for
gas burner without fan, with ignition
burner intermittent and exhaust gas
monitoring
DGAI. 69F
129
X 1
X 2
127
140
Pole Coding
no.
Plug no.
41
02
....
1)
02 K04
1)
34
02
....
02 K16
02
....
1)
02 K05
1)
50
03
....
03 K04
41a
02
....
1)
02 K06
02
....
1)
02 K44
54
02
....
1)
02 K03
35
02
....
1)
02 K16
1)
36
02
....
02 K16
11
01
Flat-type plug
6.3 x 0.8 mm
Head Offices and Factory
Karl Dungs GmbH & Co. KG
Siemensstraße 6-10
D-73660 Urbach, Germany
Telephone +49 (0)7181-804-0
Fax +49 (0)7181-804-166

Specifications

Nominal voltage
Frequency
Performance rating
Internal fuse
Back-up fuse
Switching capacity:
Fault signal
signal)
Ignition
Ignition gas valve
Main gas valve
LP gas valve
Total switching capacity
Flame detector
Ionisation current / operation
Switch-off sensitivity
Short-circuit current limitation
Unlock facility
Degree of protection
Ambient temperature
Connectivity
Protective grounding terminal
Weight
Exhaust gas sensor
Nominal resistance
Switch-off resistance
Switch-on resistance
Ignition
Order data
Automatic gas burner control
Connectors
Manufacturer:
Postal address
Karl Dungs GmbH & Co. KG
Postfach 12 29
D-73602 Schorndorf, Germany
Internet www.dungs.com
230 V AC - 15 % to 240 V AC + 6 %
50 Hz
approx. 5 VA
(not replaceable)
max. 6 A slow-blow or 10 A quick-acting
max. 1 A (with external fault
max. 1 A
max. 1 A
max. 1 A (with operating signal)
max. 1 A
max. 2 A
lonisation
6 - 10 µA
<1 µA (≥ 0.5 µA)
approx. 100 µA
Remote unlock
IP 20 - IP 40 must be
ensured by installation
0 to 60 °C
Rast 5, encoded
Separate protective ground conduc
tor
0.35 kg
Not contained in scope of supply
at 25 °C approx. 1 MΩ
at 65 °C approx. 150 kΩ
at 55 °C approx. 230 kΩ
External ignition source
Type
Order No.
DGAI. 69F
as per spec.
Not contained in scope of supply.
Connection can only be per-
formed using RAST5 connectors,
row 36... encoded.
Lumberg GmbH & Co.
D-58569 Schalksmühle
4 ... 4