Danfoss APP 0.6 Instrukcja serwisowa
Service guide | Disassembling and Assembling, APP 0.6-1.0

3. Change of shaft seal

© Danfoss | DCS (im) | 2017.08
5. Mount flushing valve by pressing it into
the hole.
Tools needed
6. It must be pressed down so it levels with
the surface of the port flange (same level).
In order to find out if the valve is
working correctly, the pump needs to
be further dismantled. To work correctly
a small flat edged wire is pushed against
the flushing valve. You should be avle to
move it a couple of mm and feel the load
of the spring pressing backwards.
Recessed
screws
1. Unscrew the 4 mounting screws and
remove the seal SAE flange.
Do not unscrew the 2 recessed screw at
this time.
2. Wet the shaft and shaft seal with
clean (filtered) soap-water. Gently lever
the shaft seal assembly free with the aid of
2 screwdrivers.
180R9092| DKCFN.PI.013.EC5.02 | 521B0739| 7