6
Disassembling and assembling APP 11-13 and APP 16-22
14.
Remove the retainer guide, the spring
guide, the 7 springs and the 3 pins.
16.
Place cylinder barrel horizontal to ensure it
can not roll. For further disassembling of
cylinder barrel and valve plate see page 13.
17.
Remove the port plate.
19.
Place the pump horizontally.
180R9228 / 521B1181 / DKCFN.PI.013.A2.02 / 10.2013
15.
Mount the M8 eye bolt in the cylinder
barrel. Pull straight upwards. A continuous
lift will elevate cylinder barrel out of
housing. This can only be done if shaft seal
is removed.
WARNING: If the cylinder barrel is
dropped into housing, the shaft bearing
in the port flange might be damaged.
Replacement of the shaft bearing in the
port flange can then only be done at
Danfoss DK-Nordborg.
18.
Remove the two guide pins.