Danfoss APP 2.5 Instrukcje demontażu i montażu - Strona 3

Przeglądaj online lub pobierz pdf Instrukcje demontażu i montażu dla Pompa wodna Danfoss APP 2.5. Danfoss APP 2.5 12 stron.
Również dla Danfoss APP 2.5: Instrukcja obsługi (8 strony)

Danfoss APP 2.5 Instrukcje demontażu i montażu
Service guide | Disassembling and Assembling, APP 1.5-3.5
1. Disassembling and
assembling the pump
© Danfoss | DCS (im) | 2017.08
1. Unscrew the 4 mounting screws and
remove seal SAE flange.
Do not yet unscrew the 2 lower screws.
3. Unscrew the 2 lower screws.
5. Remove the housing.
2. Wet the shaft and shaft seal with clean
(filtered) soap water. Gently lever the shaft
seal assembly free using 2 screwdrivers.
4. Carefully turn the whole pump over so
that the shaft is facing down. Support the
pump in a suitable hollow base so that the
pump is not supported by the shaft.
APP 1.5-2.5
APP 3.0-3.5
6. Remove the pistons, retaining plate,
retaining ball, spring guide, and spring
from the cylinder barrel.
180R9091| DKCFN.PI.013.EF5.02 | 521B0741| 3