Danfoss APPW 5.1 Instrukcja serwisowa - Strona 11

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Danfoss APPW 5.1. Danfoss APPW 5.1 12 stron. Disassembling and assembling

Danfoss APPW 5.1 Instrukcja serwisowa
Service guide | Disassembling and Assembling, APP(W) 5.1-10.2
© Danfoss | DCS (im) | 2017.06
17. Push the new ceramic ring into the
retaining ring, using the plastic tool
provided.
Make sure the face with the rubber seal is
positioned against the shoulder in the
retaining ring (see drawing on last page).
19. To prevent cold welding, lubricate the
thread and O-ring on the retaining ring
with grease, screw it into the pump and
tighten it by hand. Use Molykote® D paste
from Dow Corning or Klüber UH1 84-201
from Klüber lubrication.
20. Remount the retaining ring and tighten
by hand.
Seal retaining ring
Ceramic ring
Stop bush
18. Remove the old O-ring and fit the new one
on the retaining ring (see also drawing on
last page).
21. Tighten the retaining ring to a torque of
60 ± 5 Nm using the tool provided.
Rubber seal
Carbon ring
O-ring
180R9238 | DKCFN.PI.078.F3.02 | 521B1196 | 11