14
14
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
22.
Wet the shaft seal with water and mount it
in the front cover. Ensure that it is pressed
to the bottom.
24.
Mount the spring.
26.
Wet the shaft seal and slide it over the
bush.
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
23.
Mount the washer with the edge pointing
upwards.
25.
Fit the hollow bush onto the shaft.
27.
Use the shaft seal tool when pressing the
shaft seal downwards.