Danfoss PAHT C 2-6.3 Instrukcja serwisowa - Strona 9
Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Danfoss PAHT C 2-6.3. Danfoss PAHT C 2-6.3 20 stron. Pah 2-6.3/paht 2-6.3/paht c 2-6.3 and paht g 2-6.3 disassembling and assembling
Instruction
3.
Assembling
Disassembling and assembling PAH 2-6.3, PAHT 2-6.3, PAHT C 2-6.3 and PAHT G 2-6.3
2. Remove swash plate and guide pin.
WARNING:
Do not use silicone when assembling the
pump. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
1. Lubrication:
• To prevent seizing-up, lubricate all
threads with PTFE lubrication type.
• O-rings inside pump may be lubricated
only with clean filtered water.
• O-rings for port flange, mounting flange
and flushing valve must be lubricated.
• It is important to lubricate ALL parts to
be assembled with clean filtered water
(Especially all PEEK parts).
180R9094 / 521B0985 / DKCFN.PI.011.N5.02 / 09.2015
Guide pin
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolute clean before mounting.
2. Parts and tools required for assembly.
Check that all parts are OK. Replace all
seals.
9