DPM_LIMITING: 40107
The address contains the status of the DPM function:
•
0 = function disabled
•
1 = function enabled. Charging current limited by the DPM
TEMP_DERATING_STAUTS: 40108
The address contains the status of the current derating function:
•
0 = function disabled
•
1 = charging current limitation function enabled due to operation in overtemperature.
The function is enabled when the temperature overcomes 85°C
RTU_ADR: 40200
The address contains the current charging station Modbus Bus address, which is between 1 and
32.
The default value is set to 1.
NEW_RTU_ADR: 40201
The address is used for setting the new Modbus Bus address. Insert in this field the new value
that will identify the charging station.
The default value is set to 1.
ACTIVATE_NEW_RTU_ADR: 40202
The address is used for the activation of a new Modbus Bus address. Enter 0x5555 to activate
the new Modbus Bus address inserted in the address 40201.