CAUTION!
ISK OF ELECT IC SHOCK
DO NOT OPEN
O REDUCE HE RISK OF ELEC RIC SHOCK DO NO REMOVE COVER
NO USER -REMOVEABLE PAR S INSIDE
REFER SERVICING
O QUALIFIED PERSONNEL
DVERTISSEMENT : RISQUE DE CHOC ELECTRIQUE-
NE P S OUVRIR
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
ead these instructions.
Keep these instructions. In the event that you pass the product to a third
party this instruction manual should be provided along with the product.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings.
Install in accordance with the manufacturer's instructions.
Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding type plug.
A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The
wider blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of
the obsolete outlet.
Protect the power cord from being walked on or pinched, particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.

7: Specifications

8000Q Pre-amplifier
Inputs: Gain and Sensitivity
CD, TUNER, AUX, VIDEO, TAPE 1, TAPE 2: IMPEDANCE: 20k
GAIN: Adjustable by 3dB steps 0 -15dB., corresponding to
SENSITIVITY(nom.): 100, 140mV, 200mV, 283mV, 400mV, 562mV
HEADPHONES: Gain adjustable 18dB - 33dB in 3dB steps
(IHF, rel. 0.5V output)
Signal To Noise Ratio
Any input, any gain setting: 97dB
Headphones: 80dB
Frequency Response
10 Hz-20 kHz ±0.2 dB: 1 Hz-75 kHz -3 dB.
Total Harmonic Distortion & Noise
Less than 0.007 % ref 7.7V rms, 20Hz - 20kHz
Channel Balance
Within 1 dB
Channel Separation
Better than100 dB @ 1 kHz any input, any setting
Pre-amp Output
Max. Output >7.7 V RMS (20dBm); Output impedance 75
Headphone Output
>7.7Vrms;100
(for headphones 8 -2 k impedance)
Record Output
VIDEO OUT, TAPE 1 OUT, TAPE 2 OUT: Gain 0 dB (x1); 100
Muting
Attenuation>63 dB, controlled automatically
Operating Temperature Range
10-35 °C
(Depending on Region)
Power Requirements
50-60Hz 100V, 110-120V, and 220-240V models available
Maximum Power Consumption: 15 VA
(WXHXD)
Dimensions
445x74x335 mm - including feet, terminals and controls
445 x 64 x 302 mm- excluding feet, terminals and controls
Weight
Net: 6 kg Shipping:7.3 kg
Use only attachments/accessories specified by the manufacturer.
Use only with a cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long
periodsoftime.
Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
Warning:
To reduce the risk of fire or electrical shock, do not expose this
product to rain or moisture. The product must not be exposed to dripping
and splashing and no object filled with liquids such as a vase of flowers
should be placed on the product.
No naked flame sources such as candles should be placed on the
product.
Caution:
Changes or modifications not expressly approved by the
manufacturer could void the user's authority to operate this device.
8000Q
: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio or television reception, which can be
determined by tuning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
Re-orientate or re-locate the receiving antenna. Increase the separation
between the equipment and the receiver. Connect the equipment into an
outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Important Note:
The batteries supplied with the 8000Q handset should
be treated with care and not punctured or damaged. Used batteries
should be disposed of in full conformity with recycling regulations in your
area. NEVER dispose of batteries in a fire or in the general rubbish.
8000P Power Amplifier
Rated Output Power
100W (20dBW) /Channel into 8 both channels driven
Input
1V rms for 100W into 8
Input Impedance: 50k
Load
Connected in parallel with INPUT
Gain
29.0 dB at1kHz
(IHF, rel. 0.dBW)
Signal To Noise Ratio
Better than 95 dB
Frequency Response
20 Hz-20 kHz ±0.3 dB
0.1 Hz-75 kHz -3 dB.
Total Harmonic Distortion & Noise
Less than 0.05 %
Channel Balance
Within 1 dB
Polarity (Phase)
Non-Inverting
Muting
Muting controlled automatically
Operating Temperature Range
10-35 °C
(Depending on Region)
Power Requirements
50-60 Hz 100V, 110-120V, and 220-240V models available
Maximum Power Consumption: 500 VA
(WXHXD)
Dimensions
445x74x337 mm - including feet, terminals and controls
445 x 64 x 302 mm- excluding feet, terminals and controls
Weight
Net: 8.7 kg Shipping:10 kg
Mains supply and safety
Mains Supply:
The mains voltage of Audiolab units is shown on the rear
panel. If this does not match the voltage in your area, consult your dealer.
The mains supply fuse is on the rear panel. If it has broken, check for any
obvious cause before replacing the fuse with one of the correct rating and
type. The fuses for all areas are type T (time lag ) AL 20mm.
The fuse values are:
8000Q:
220-240V:
1.0A
100-120V
: 1.6A
8000M: 220-240V:
3.15A
100-120V
: 5.0A
8000P:
220-240V: 4
.0A
100-120V
: 5.0A
The fuse is located in a slide-in
use Carrier
carrier which also contains a spare
fuse. The carrier can only be pulled
out after the IEC power cord is
unplugged. When the carrier is
opened the first fuse is the spare.
Remove and safely dispose of the
blown fuse before replacing it.
IEC Mains Connector
Class II construction double insulated. These products must not
be connected to earth.
Power Cord:
An AC power cord is normally supplied with a mains plug
suitable for your area. If you have any doubts, consult your dealer about
obtaining a suitable power cord.
Important notice to UK users
The appliance cord is terminated with a UK approved mains plug fitted
with a 5A fuse. If the fuse needs to be replaced, an ASTA or BSI approved
BS1362 fuse rated at 5A must be used. If you need to change the mains
plug, remove the fuse and dispose of this plug safely immediately after
cutting it from the cord.
Connecting a Mains Plug
he wires in the mains lead are colouredin accordancewith the code:
Blue: NEU RAL;
Brown: LIVE:
As these colours may not correspond to the coloured markings identifying
the terminalsin your plug, proceedas follows:
he BLUE wire must be connected
to the terminal marked with the
letter N or coloured BLUE or
BLACK. he BROWN wire must be
connected to the terminal marked
BLUE
with the letter L or coloured
(Neutral)
BROWNor RED.
8000M Power Amplifier
Rated Output Power
125W (21dBW) /Channel into 8 , 20Hz - 20kHz
Input Sensitivity
1.12V rms for 120W into 8
Input Impedance: 50k
Load
Connected in parallel with INPUT
Gain
29.0 dB at1kHz
(IHF, rel. 0.dBW)
Signal To Noise Ratio
Better than 96 dB
Frequency Response
20 Hz-20 kHz ±0.3 dB
0.1 Hz-75 kHz -3 dB.
Total Harmonic Distortion & Noise
Less than 0.05 %
Polarity (Phase)
Non-Inverting
Muting
Muting controlled automatically
Operating Temperature Range
10-35 °C
(Depending on Region)
Power Requirements
50-60Hz 100V, 110-120V, and 220-240V models available
Maximum Power Consumption: 300 VA
(WXHXD)
Dimensions
445x74x337 mm - including feet, terminals and controls
445 x 64 x 302 mm- excluding feet, terminals and controls
Weight
Net: 8.2 kg Shipping:9.6 kg
Audiolab reserves the right to alter design and specification without notice.
Specification may vary for different countries.
Audiolab is a member of the International Audio Group.
5A FUSE
BS 1362
BROWN
(Live)