On the EDFAMUX management GUI, verify that the EDFA Post Amp (referred to as
POST EDFA on the management GUI) values match the table included in the
"Recommended EDFA Values" part of this document. If the output value does not
match, adjust the Booster and Post-Amp values accordingly.
13.
Before connecting each DWDM optic to the corresponding channel on the
EDFAMUX, use an optical power meter or a DWDM OSA meter to verify that the TX
values of the EDFAMUX channel are lower than:
14.
If the values are under the limits as described, the optics may be connected to the
corresponding channel on the EDFAMUX using single-mode fiber patch cables.
15.
If values are too low, you can fine-tune the EDFAMUX configuration (based on
Figure 1) using the following steps:

2. Network Configuration

Ethernet Configuration
In the Ethernet configuration submenu, the following operations can be performed:
1.
Enable Static IP (by default the EDFAMUX will use DHCP) (1).
2.
Perform a "Ping" (for troubleshooting or verification):
In the case of the 100G EDFAMUX: 8dBm (aggregate damage threshold of
the optic).
In the case of the 10G EDFAMUX: -7dBm.
Click "manually override amplification values" (2).
Modify the PRE and POST EDFA (3).
Click on "Apply changes" (4).
Repeat the operation in the second site of the EDFAMUX and verify the
values before connecting the DWDM optics.
When enabled, IP Address (2), Gateway (3), and Subnet mask (4) must be
configured.
When changes are complete, click "Save" (5).
Fill in the destination IP address (6) and click on "Ping" (7).