Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a qualified electrician.
Make sure the power is isolated from the circuit.
2. CEFL PIR LR should be installed to achieve correct coverage of the
working area (diagram B).
3. The greatest energy savings will be made if the CEFL PIR LR
individually controls a set of lamps. They can be wired in parallel
but this should ideally be limited to three or less.
4. The CEFL PIR LR should be connected as:
L
Live in
N
Neutral in
SL
Switched Line out
5. Typical wiring diagrams are shown in diagrams D and E.
6. Once the wiring has been completed and verified, switch on the
supply and test the operation.
Start-up mode
When the CEFL PIR LR is powered up, it will switch on the load for 1
minute, it will then switch off and enter its Operating Mode. If a manual
override-off switch is positioned before the CEFL PIR LR it will do this each
time it is switched back to Operating Mode. Alternatively, if the wall switch
is placed after the CEFL PIR LR it will not enter the start-up mode.
Lux set-up
Ensure that the TIME is set to the minimum when setting up the LUX
level, afterwards set the TIME to a value suitable for the application.
The LUX is best set up when the local ambient light is at approximately
the minimum desired working light level, a lux meter placed on the
working surface may help. With the LUX set fully clockwise wait for the
PIR to switch off. Rotate the LUX adjuster slowly anticlockwise (- to +),
whilst waving your hand approximately 1m below the CEFL PIR LR,
until the load switches on.
This LUX setting point can be used for other devices located where the
current lighting level is not at the desired minimum working level.
A: Mounting diagram
Springs can either be
Clearance hole
left closed (down the side of the
63 or 64mm
product) or opened out.
(2.5") diameter
C: Adjusting time and lux
Typical settings
2m30s
1m15s
5m
40s
10m
20s
20m
1000
∞
10s
40m
100
min
max
max
min
TIME
LUX
D: Wiring diagram, single PIR
Note 1: Optional
Note 2: Alternative
position for optional
manual wall switch
wall switch
for overriding off.
L
SL
L
N
230 VAC
N
E: Wiring diagram, multiple PIRs
Note 1: Optional manual wall switch
for overriding off
L
L
L
N
N
SL
SL
230 VAC
N
B: Detection diagram
Recommended
mounting height
up to 20m
6°
Detection
zone for
person
walking
up to 2m
load
Note 2: Alternative
position for optional
wall switch.
L
N
SL
load