Audioroot eSMART TRIO Podręcznik - Strona 10
Przeglądaj online lub pobierz pdf Podręcznik dla Jednostka dystrybucji zasilania Audioroot eSMART TRIO. Audioroot eSMART TRIO 11 stron. Advanced portable smart battery power distributor
Battery #1 is the battery connected to power input #1
Battery #2 is the battery connected to power input #2(
Battery #3 is the battery connected to power input #3(
USB OUTPUTS :
The eSMART TRIO has 2 USB power outputs located on the front panel of the unit.
The USB type C connector
in 5 different schemes :
5V @ 3A
•
9V @ 3A
•
12V @ 3A
•
15V @ 3A
•
•
20V @ 2.2A
The power delivery scheme is negotiated automatically between the eSMART TRIO and
device connected to the USB-C port
The USB type A connector
power in 3 different schemes :
5V @ 2.4A
•
9V @ 2A
•
12V @ 1.5A
•
QC 3.0 power is negotiated automatically between the eSMART TRIO and device connected
to the USB-A port
(5)
.
A red LED
(15)
shows the power status of the USB internal sub-circuitry.
TA4F POWER + smBUS AGGREGATED OUTPUT :
The TA4F output connector
smart batteries connected to the system. This output delivers up to 5A of current and can be used
to power an smBUS capable device (such as Sound Devices™ mixers/recorders) or to extend
output capabilities via another smart battery distributor such as the eSMART BG-DU.
ACTIVE OUTPUT SHORT CIRCUIT/OVER CURRENT DETECTION :
The eSMART TRIO has a unique active short circuit/over current monitoring system which
helps the user troubleshooting faulty equipment and/or cables.
In the event of a short circuit (or overcurrent condition) on any of the eSMART TRIO's
outputs the distributor will shut down all outputs to prevent catastrophic failure. A red popup
screen will inform the user that a short circuit has been detected and that cables/devices should be
checked. The eSMART TRIO will automatically try to restore power within 40 seconds. If the short
circuit condition has been removed power will be restored. If not the eSMART TRIO will keep all
outputs off and will retry restoring power every 40 seconds.
In most cases short circuits happen in bad or poorly assembled power cables : a solder
connection looses up and shorts battery power to ground. Removing the faulty cable will solve the
issue. More rarely an overcurrent can be caused by a faulty device connected to the TRIO. In that
case disconnecting the bad device will clear the fault.
http://www.audioroot.fr [email protected]
Ce document est la propriété d'AUDIOROOT, et ne peut-être reproduit ou communiqué sans autorisation
Battery serial numbers
(3)
is Power Delivery capable and can output up to 45W of power
(3)
.
(5)
is Quick Charge 3.0 compatible and can output up to 15W of
(3)
outputs power and aggregated smBUS information from all
(10)
11)
12)