3.2 Installation
The installation of the stove must be carried out by qualified people who are aware of the safety
measures regarding the stove installation. A badly installed stove can cause serious accidents (chimney
fires, burning of insulating materials, etc).
3.3 Lighting the stove for the first time
The first time the stove is lit, there will be smoke and odor given off due to the drying of the protective color.
That is normal, because the color stabilizes on temperatures over 350°C.
THE ROOM MUST BE PROPERLY VENTILATED.
Before the lighting, all parts should be cleaned with a dry cloth to remove dust and impurities.
- Upon the first ignition of the stove, we suggest loading recommended quantity of fuel reduced to half in
order to test the stove.
3.4 Ventilation of the room
Good ventilation is essential in order to provide proper operation without any risk to people who use the
room where the stove is installed, because during the combustion the stove uses the oxygen from the air. It
is necessary that the room has adjustable air openings.
ATTENTION
In case of non-observance of the indications, the manufacturer disclaims all responsibilities.
Modifications on the stove are not allowed.

4. THE FLUE

Special attention must be paid to the quality of the flue which must be made in accordance with the
standards. The flue must be regularly maintained. The stove is connected to the flue through a connection
on the upper or back side of the stove, by the appropriate smoke pipes. The smoke pipe must not be
positioned too deep in the flue so as not to decrease the surface of the cross-section and, in that manner,
disturb the draft in the flue.
The draught in the flue
An inadequate draught is exclusively the main reason behind most complaints of poor stove operation!
Necessary draught for this type of stove is 12 Pa.
A lower value does not permit proper combustion with the consequent formation of carbon deposits and
excessive production of smoke, which, being unable to flow to the exterior will escape through the grills or
door.
If the draught value is too high, combustion will be too fast, with the consequent dispersion of the heat
through the flue. If the draught is greater than 15Pa, the elements for draught reduction should be installed.