Customer/Visitor Side Installation
1. Check that there is at least 50mm of free space below the customer side
of the counter top for the speaker and microphone pods.
2. Ensure there is access to the wiring under the counter once installed.
3. Mark the cut-out dimensions in the diagram below onto the counter top
twice, adjacent to either side of the pass-through tray. The recommended
distance between each cut-out marking is 500mm.
R6
52
4. Use a router to cut out two areas for the flush mounted speaker and
microphone pods, routed to a depth of 1.5mm.
Recess (hatched)
107
Cut-out
97.5
120
Speaker and microphone pod
container cut-out
15
54
65
5
7