SECURICOM SPEECH TRANSFER SYSTEM
System Components
Siting and Installing the Amplifier
Siting and Installing
Microphones and Speakers
10
1. STS A20 audio amplifier (or A30 version for loop facility)
2. STS-P41/P42 12V DC power supply (or P43 PSU for loop facility)
3. STS-F70 Staff Unit comprising close speaking microphone and loud speaker
4. A microphone for the Customer
5. A loudspeaker for the Customer
6. Induction Loop Aerial (optional)
N.B. Microphones and Loudspeakers are available in flush or surface mounting formats.
The STS-F70 Staff Unit for the staff side is supplied as standard. An alternative option comprising
separate microphones and loudspeakers is also available.
A Customer Audio Bridge with twin surface mounted loudspeakers and a centrally fitted close
speaking microphone is available for the Customer's side.
Typical SecuriCom set up using flush mounted components on the Customer's side
Power
Supply
Unit
220/240
VAC
50Hz
contacta
POWE
CUSTOM
STAF
STS-A 20/30
Each SecuriCom system requires one Audio Amplifier (STS-A20 or STS-A30) with its associated Power
Supply (STS-P41/42 or STS-P43). The Amplifier connects on a plug and socket basis to other system
components via individual cables.
The Amplifier should be mounted on a flat surface within close proximity to the other system com-
ponents and conveniently to hand for the operator. For example, on the staff side under the desk-top
or counter-top would be suitable. Ensure there is also access to the Microphone and Induction Loop
gain controls located on the side of the amplifier and also to the rear connection sockets before fix-
ing. Twin flanges each with two screw holes are formed at the top of the amplifier housing.These are
used to fix the amplifier under the counter top with small self tapping screws.. The Amplifier housing
need not be opened as all connections are external.
Customer Microphones and Loud Speakers may be flush or surface mounted depending on individual
requirements. See following pages for fitting instructions. Surface mounted components are best sited
at the junction between the counter-top and the glass partition. For best performance, the Microphone
should be mounted at least 30 centimetres away from the Loudspeaker. Each component comes with
a 3 metre lead and two-way plug. It is advisable to remove the plug before fixing as this enables a
neater installation to be achieved using smaller diameter holes through which to feed the cables.
However, the cables and plugs must be re-connected correctly or the system will not operate. If in
doubt, identify and mark the wires before disconnecting the plug(s).
and combined Staff Unit for Staff.
Customer side
Minimum distance between loudspeaker
and microphone 30 cms
Cash Tray
STS Amplifier mounted
below counter-top
Staff side

INSTALLATION

Security Screen
STS-F70
Staff Unit