RESISTANCE MEASUREMENT
Red lead to "VΩmA". Black lead to "COM".
Set RANGE switch to desired Ω position.
If the resistance being measured is connected to a circuit, turn off power and
discharge all capacitors before measurement.
Connect test leads to circuit being measured.
Read resistance value on the display.
DIODE MEASUREMENT
Red lead to "VΩmA", Black lead to "COM".
Set RANGE switch to "
Connect the red test lead to the anode of the diode to be measured and black
test lead to cathode.
The forward voltage drop in mV will be displayed. If the diode is reversed,
figure "1" will be shown.
TRANSISTOR hFE MEASUREMENT
Set RANGE switch to the hFE position.
Determine whether the transistor is PNP of NPN type and locate the Emitter,
Base and Collector leads. Insert the leads into the correct pins of the hFE
socket.
The meter will display the approximate hFE value at the condition of base
current 10μA and VCE2.8V.
AUDIBLE CONTINUITY TEST
Red lead to "VΩmA", Black lead to "COM".
RANGE switch to "
Connect test leads to two points of circuit to be tested. If the resistance is
lower than 30Ω ± 20Ω, the buzzer will sound.
TEST SIGNAL
Set RANGE switch to "
A test signal (50Hz) is produced between "VΩmA" and "COM" jack.
The output voltage is approx 5V p-p with 50KΩ impedance.
NOTE: OVERLOAD PROTECTION: 15 seconds maximum 220Vrms.
" position.
" position.
" position.