Duratool D03145 Skrócona instrukcja obsługi - Strona 5

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Multimetr Duratool D03145. Duratool D03145 7 stron. Multimeter with automotive ranges

OHM

DWELL ANGLE

TACHO

AC & DC VOLTAGE MEASUREMENT
Set the function range switch at the required position.
Connect the black test lead to the "COM" terminal and the red test lead to the "VΩ"
input terminal.
Connect the test leads to the measuring point and the polarity of the red lead
connection will be indicated at the same time as the voltage, on the LCD.
If the voltage to be tested is unknown, set the Function Range switch to the
highest range.
Note: When only figure "1" is displayed, overrange is being indicated and the function
range switch should to be set to a higher range.
WARNING: Do not attempt to measure voltage above 1000V as there is a danger of
AC & DC CURRENT MEASUREMENT
Connect the black test lead to the "COM" terminal and the red test lead to the
"mA" terminal for a maximum of 0.2A.
Set the function range switch at the required position.
Connect the test leads to the measuring points and read the display value. The
polarity at the red test lead connection will be indicated at the same time as the
current.
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
Range
Scope (°)
4 CYL
0 ~ 90
6 CYL
0 ~ 60
8 CYL
0 ~ 45
Range
Scope (°)
4 CYL
20,000
6 CYL
PRM
8 CYL
damaging the internal circuitry.
Resolution
0.1Ω
10Ω
100Ω
1kΩ
10kΩ
Resolution
0.1°
Resolution
10 x RPM
5
Accuracy
± (1.0% ± 10)
± (1.0% ± 4)
± (1.0% ± 10)
Accuracy
± (2.0%
± 5)
Accuracy
± (1.5%
± 5)