DURASTACK™ PRO 
 
MODELS DCL, DAS1, DIS1, DIS2, DIS4
 
 
DCL- SINGLE WALL
DAS1- AIR INSULATED
DIS1, DIS2, DIS4 – FIBER INSULATED

SECTION A - CODE COMPLIANCE

UNDERWRITERS LABORATORIES LISTINGS
DURAVENT single wall Model DCL and double wall models DAS1, DIS1, DIS2 and DIS4
venting systems are listed by Underwriters Laboratories, Inc. (UL) in the following
product categories and in the diameters indicated:
Model D A S - P R O (DAS1 - Double wall, 1" air insulation)
Building Heating Appliance Chimney
1400° Fahrenheit Chimney
Models D I S - PRO (Double wall, DIS1, DIS2 or DIS4) where the number
equals ceramic fiber insulation thickness
Building Heating Appliance Chimney
1400° Fahrenheit Chimney
Building Heating Appliance Chimney(Type HT)
APPLICATION
UL 103 Building Heating Appliance Chimney
Listing:
Under this category, models DAS-PRO and D I S -PRO have been determined suitable
for venting flue gases at temperatures not exceeding 538°C (1000°F) under
continuous operating conditions from gas, liquid, oil or solid fuel fired appliances. Also
complies with operation (less than one hour) at temperatures not exceeding 740°C
(1400°F) and brief operation (maximum 10 minutes) at temperatures not exceeding
906°C (1700°F). Building Heating Appliance Chimneys are suitable for use with
Building Heating Appliances and Low Heat Appliances as described in the Chimney
Selection Chart of National Fire Protection Association (NFPA) Standard NO. 211.
Building Heating Appliance Chimney (Type HT) Listing 5" to 24" DIS-PRO
ONLY
Under this category (UL 103HT), the 5" through 24" ID DIS-PRO Models have qualified
for UL's additional, optional "Type HT" rating (for Building Heating Appliance
Chimneys) which indicates they have been evaluated and found suitable for exposure
to 2100°F flue gases for a 10 minute duration at a specific clearance for each
Model and diameter. Many local, state and regional code authorities require a
"Type HT" rating for chimneys for certain appliance venting applications; especially
solid fuel.
Building Heating Appliance Chimneys are suitable for use with Building Heating
Appliances and other Low Heat Appliances as described in the Chimney Selection
Chart of National Fire Protection Association (NFPA) Standard No. 211.
1400°F Chimney Listing - Under this category (UL 2561,ULC-C959), Model D A S -
PRO and DISX-PRO have been determined suitable for venting flue gases continuously
at a temperature not exceeding 1400°F, and a 10 minute intermittent service at
temperatures not exceeding 1800°F. As such, Model DAS-PRO and D I S -PRO
Models are suitable for use with ovens and furnaces as described in the Chimney
Selection Chart of NFPA No. 211, in addition to other Applications.
 
Engine Exhaust
Based upon the above referenced UL Listings and supplemental, UL confirmed
pressure testing, Model D A S -PRO and D I S -PRO are also suitable for use as
complete exhaust systems for diesel engine and gas turbines. When Model DAS-PRO
and DIS-PRO is used as an engine or turbine exhaust it is intended to be installed in
accordance with NFPA 37 "Stationary Combustion Engines and Gas Turbines". This
code states, "When such (flue gas) temperatures do not exceed 1000°F (538°C)
except for infrequent, brief periods, the engines shall be classified as low heat
appliances". For continuous operation over 1000°F and not exceeding 1400°F the
exhaust system should be installed as a 1400°F Chimney.
Models D I S -PRO may be used to meet various needs, such as:
Models DAS-PRO and D I S -PRO exhaust systems are intended for use in connecting
5"- 36" ID
the heating appliance, engine, or turbine to the outdoors, while operating under
positive forced draft, negative induced draft or neutral gravity flow internal
5"- 36" ID
pressure conditions. Models DAS-PRO and D I S -PRO (all insulation thicknesses)
may be intermixed in the same chimney system, assuming the proper associated
airspace clearances-to-combustibles are maintained.
ADDITIONAL
5"- 36" ID
APPLICATIONS
5"- 36" ID
Models D CL, DAS1 and D I S -PRO are also suitable for negative, neutral or positive
pressure pre- fabricated piping systems intended for use in a variety of
5"- 36" ID
applications including but not limited to the following:
Particle Conveying, Dryer Vents and Ventilation Ducts.
SUITABLE FOR POSITIVE PRESSURE VENTING APPLICATIONS WITH MAXIMUM 60"
WATER COLUMN INTERNAL STATIC PRESSURE AT 1000 DEGREES F.
MULTI-ENGINE
EXHAUSTS
A common exhaust system for multiple engine or turbine installations is generally not
recommended. Check with your engine or turbine manufacturer prior to common
exhaust system design. Exhaust gas from operating units tends to flow to non-
operating units where condensation may form. Water in engine or turbines at start-up
may cause damage. In general, a separate exhaust system should be provided for
each engine or turbine.
S
R
D
S
UBMITTAL 
ECORD FOR 
URA
TACK 
M&G
D
V
|
10
J
 
URA
ENT 
 
 
www.duravent.com 
a) Reduce outer pipe surface temperature.
b) Reduce building heat gain by retaining energy inside the vent.
c) Increase the efficiency of energy recovery systems by reducing exhaust
gas temperature losses.
d) Increase chimney or exhaust system draft loss performance due to
reduced exhaust gas temperature drop.
e) Reduce building noise levels caused by high speed or pulsating exhaust
induced noise. NOTE: Specific tests have not been conducted to measure
acoustic performance.
M
DCL,
DAS1,
DIS1,
DIS2
ODELS 
 
 
 