4B P300 Series Instrukcja obsługi - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Akcesoria 4B P300 Series. 4B P300 Series 16 stron. Inductive proximity sensor

All wiring must be In accordance with local and national electrical codes and should be undertaken by an
experienced and qualified electrician.
Where necessary, use dust/liquid tight flexible metal conduit with approved fittings to protect the sensor
cables. Use rigid metal conduit to protect the cables from the sensors to the control unit. Conduit systems
can channel water due to ingress and condensation directly to sensors and sensor connections which
over time will adversely affect the performance of the system. As such, the installation of low point conduit
drains is recommended for all sensors.
1500A capable fuse with 500mA maximum rating MUST be used for each sensor in order to comply
with ATEX wiring regulations.

STANDARD WIRING DIAGRAM

P3003V10AI
WARNING
PAGE 10
P3004V10AI