Aplex TB-587 Podręcznik użytkownika - Strona 9

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Systemy wejścia/wyjścia Aplex TB-587. Aplex TB-587 10 stron. Machine vision lighting & i/o control board

Signal
GP_OUT8
GP_OUT7
GP_OUT6
GP_OUT5
GP_OUT4
GP_OUT3
GP_OUT2
GP_OUT1
GND_24V_GPIO
NA
CTRL_OUT4_N
CTRL_OUT4_P
CTRL_OUT3_N
CTRL_OUT3_P
CTRL_OUT2_N
CTRL_OUT2_P
CTRL_OUT1_N
CTRL_OUT1_P
NA

8. TB-587-DB37:

Standard DB37 Female connector inserts, 4 x Trigger In (4x dedicated input channels, 24V
differential signal, with isolated.)
TI1+,TI1-, TI2+,TI2-,TI3+,TI3- ,TI4+,TI4-
---Combined to DB-37connector
4x Trigger Out (4x dedicated output channels, 24V differential signal, with isolated.)
TO1+, TO1-, TO2+, TO2-, TO3+, TO3-, TO4+, TO4-
---Combined to DB-37connector
16x High-speed General I/O, can switch to NPN or PNP through hardware, default NPN setting,
24V level Optocoupler isolation design.
GND_24V_GPIO, DO1, DO2, DO3, DO4, DO5, DO6, DO7, DO8
24V_GND_GPIO, DI1, DI2, DI3, DI4, DI5, DI6, DI7, DI8
---Combine to DB-37connector
Pin#
Pin#
1
20
2
21
3
22
4
23
5
24
6
25
7
26
8
27
9
28
10
29
11
30
12
31
13
32
14
33
15
34
16
35
17
36
18
37
19
- 9 -
Signal
GP_IN8
GP_IN7
GP_IN6
GP_IN5
GP_IN4
GP_IN3
GP_IN2
GP_IN1
24V_GND_GPIO
NA
CTRL_IN4_N
CTRL_IN4_P
CTRL_IN3_N
CTRL_IN3_P
CTRL_IN2_N
CTRL_IN2_P
CTRL_IN1_N
CTRL_IN1_P