4B Binswitch Elite BSE1V10C Instrukcja obsługi - Strona 10
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Czujniki bezpieczeństwa 4B Binswitch Elite BSE1V10C. 4B Binswitch Elite BSE1V10C 12 stron. Capacitance point level sensor
FAULT
Unexpected Operation
False / Inconsistent Readings
Sensor Not Detecting Material
BMPA MOUNT
Urethane compression
fitting mount with 1-1/4"
NPT external thread
BSM3 CLAMP MOUNT
HDP clamp style mount
TROUBLESHOOTING GUIDE
Re-calibrate sensor, if problem continues contact 4B.
1. Check that sensor is not in the direct flow of material, and
remove from flow if necessary.
2. If sensor is coated in dust, re-calibrate by following calibration
instructions.
1. If monitoring different types of materials, calibrate the sensor
sensitivity to the lightest material being monitored.
2. Re-calibrate sensor, if problem continues contact 4B.
BINSWITCH ACCESSORIES
BAS ABRASION SHIELD
Urethane abrasion shield
mount for high-abrasion or
liquid applications
A34NPT CONDUIT ADAPTER
Anodized aluminum 30 mm to
3/4" NPT conduit adapter
PAGE 10
REMEDY
SMP MOUNTING PLATE
Zinc plated steel with 1-1/4"
NPT coupling (available in
stainless steel)
BMPG36 GLAND MOUNT
Plastic gland mount