C. 3.5" Mobile Rack
1. Separate the ventilation front panel
and the metal base by removing the two
flat-head screws.
2.
Attach the 3.5" drive cradle onto
the 3.5" to 5.25" drive bay mounting
bracket at the six aligned screw hole
locations.
3.
Attach the metal base onto the
optical drive or other 5.25" storage device
using the flat head screws from the
ventilation front panel.
With the storage device connected, slide
the metal base back into the drive cage.
Secure the storage device onto the top of
the drive cage using the included screws.
7
www.addonics.com
Technical Support (M-F 8:30am - 6:00pm PST)
SRNPS - Storage Rack with No Power Supply
Connections:
1.
Connect the 20-pin ATX connector of the power supply to the 20-pin
connector on the storage rack. This connection is for the power switch on
the storage rack.
2.
Connect one of the 4-pin floppy power connector of the power supply to
the floppy power connector on the Thermal Management card.
Note: The storage rack will not turn on if power is not provided to the Thermal
Management card.
Installing the 4th Disk Array on the Storage Rack
a.
Remove the back panel of the storage rack by loosening the 4 screws
indicated below.
Screws
b.
Secure the bottom bracket of the
storage rack to the disk array using
screws.
c.
Secure the top bracket of the
storage rack to the disk array using
screws.
Phone: 408-453-6212
R
Email: www.addonics.com/support/query/
4