DaSeDa Electronics HM-75A Podręcznik - Strona 10
Przeglądaj online lub pobierz pdf Podręcznik dla Kontroler DaSeDa Electronics HM-75A. DaSeDa Electronics HM-75A 15 stron. Digital feeder controller
10-3. Parameter setting menu
You can select the parameter change menu by turning the selector.
Turn the selector to the right
Frequency -> voltage 1 -> slow up -> slow down -> number of sensors -> sensor polarity -> sensor on delay ->
Sensor off delay -> external input polarity -> external input on delay -> external input off delay -> external volume on / off
-> Constant amplitude control on / off -> Constant amplitude control time -> Voltage 2 on / off -> Voltage 2 -> Communication id setting
-> Automatic frequency setting -> Controller version display.
Turning to the left selects the opposite.
menu
Setting range
40 ~ 400Hz
Frequency
(0.1Hz unit)
0 ~ 200V
Volt 1
(0.1V 단위)
0 ~ 3sec
slow up
(0.1sec unit)
0 ~ 3sec
slow down
(0.1sec unit)
Number of used sensors
Sensor polarity setting
sensor
0 ~ 60sec
on delay
(0.1sec unit)
센서
0 ~ 60sec
off delay
(0.1sec unit)
External input
Polarity setting
Ext input
0 ~ 60sec
on delay
(0.1sec unit)
Ext input
0 ~ 60sec
off delay
(0.1sec unit)
Vibration control
on, off
on/off
Vibration Width
10 ~ 1000
Control time
(10 unit)
on, off
External volume
V2 on/off
on, off
0 ~ 200V
Volt 2
(0.1V unit)
0 ~ 32
Communication ID setting
(0 = off)
frequency
Automatic setting
Show product version
If there is no button or volume operation for 20 seconds after setting is completed, or when RUN or STOP button is pressed
The display shows the default output voltage.
"Volt LED ON"
Menu LED
Initial value
120Hz
Frequency
100V
0.1 sec
Slow Start
0 sec
Slow Start
1 ~ 2
1 EA
no,nc
no
0.1 sec
0.1 sec
no,nc
no
Ext Input
0 sec
Ext Input
0 sec
Ext Input
off
Feed Back
300
Feed Back
off
Ext Volume
off
50V
off
Show menu
Display
Volt
Sensor
Sensor
Sensor
Sensor
Volt
Volt
Selector button
Press to start.
Pressing the selector button or
Show setting value when turning