NOTICE
Tipping the spray gun causes the spray gun to clog. Dried spray material also clogs the pressure delivery tube and
fittings. The spray gun does not function when clogging occurs.
When not in use, be sure to disconnect the hose and place the spray gun into the Handi-Hold™ Docking
Station on the turbine to avoid tipping.
Improper installation of the ground plug can result in the risk of electrical shock. If repair or
replacement of the plug or cord is necessary, do not connect the ground wire to either flat blade
terminal. The wire with green insulation (with or without a yellow stripe) is the
grounding wire.
1. For any question regarding proper installation of the ground plug, consult a qualified (licensed
or certified) electrician.
2. Do not modify the plug provided. If the plug does not fit the outlet, have the proper outlet
installed by a qualified electrician.
3. This product is for use on a nominal 110-volt circuit and has a grounding plug that looks like
the plug in Figure 2. Make sure that the product is connected to an outlet having the same
configuration as the plug. Do not use adapters with this product.
4. If an extension cord is required, use only a three- w i r e extension cord that has the same
configuration as the unit cord, including the (round) ground terminal. Make sure that the
extension cord is plugged into a properly grounded receptacle.
5. When using an extension cord, be sure it is in good condition and heavy enough to meet the
specifications in the chart below. If an extension cord is needed the following wire sizes must
be used.
25' cord (7.62m).......................................................... 10, 12, or 14 Gauge
50' cord (15.24m)....................................................... 10 or 12 Gauge
100' cord (30.48m)............ ....................................... 10 Gauge
Grounding instructions for all countries using a 2 pronged plug configuration.
This product must be properly grounded. In the event of an electrical short circuit, grounding reduces
the risk of electrical shock by providing an alternate path for the electrical current.
This product is equipped with a cord that has a ground wire and an appropriate ground plug. Plug the unit into an outlet that
is properly installed and grounded in accordance with local codes and ordinances.
Safety Note: Users in countries in continental Europe and Australia and anywhere that offers a two pronged plug must be
aware that this configuration does not provide grounding.