I. FEATURES AND OPERATING CONTROLS
Before installing and operating the Gemini XLB Zero
Clearance unit, familiarize yourself with its features and
operating controls. The Gemini XLB is designed for use
with zero-clearance to combustibles. Care should be taken
when selecting a stove site. A centrally located site is
preferable, if possible, to ensure more equal heating
distribution throughout your home. If you plan to install
the Gemini XLB as a fireplace unit, the site you select for
installation and finishing construction will enhance your
present decor and heat your home more efficiently.
1. Quality Steel Construction - assures you of years of
dependable service. The firebox is constructed of 4 gauge
plated steel that is completely welded for safe, durable
installation.
2. Special Fireproof Insulation - lines the solid steel outer
box and covers the firebox to provide high temperature
resistance.
3. Warm Air Outlets - distribute the heated air from around
the firebox.
4. Front Mounted Blower - circulates air around the fire
chamber for increased heat extraction. Easy mounting
allows for quick access if service is needed.
5. Glass Door - seals the firebox for high efficiency and
allows you to see the fire.
6. Refractory Firebox Liner - boosts burning efficiency by
reflecting radiant heat back into the fire. This results in a
more thorough and cleaner burn.
7. Warm Air Deflector - on the top stove edge directs the
heated air downward and across the floor for maximum
comfort.
8. Sliding Damper - helps increase heat extraction by
controlling the escape of hot combustion gasses and smoke.
The damper is opened by pulling the control handle out
and closed by pushing the handle in. It may be left in any
intermediate position.
9. Draft controls - regulate the burning rate and the heat
output of the stove. The larger the fire, the more heat the
unit will produce. The drafts are opened by pulling the
controls outward and may be left in any intermediate
position. Start up air (centered under the door) may only be
opened during the building of the fire (5 minute max.).
10. Ash pan - for easy removal of ash.
11. Three speed switch - assists in the adjustment of air
circulation around the firebox. The automatic position is
thermostatically controlled, the blower comes on when the
activation temperature is reached. The manual position
allows for blower start up at any time.
3