AddSecure IRIS-4 160 Skrócona instrukcja instalacji i konserwacji - Strona 9

Przeglądaj online lub pobierz pdf Skrócona instrukcja instalacji i konserwacji dla Terminale dotykowe AddSecure IRIS-4 160. AddSecure IRIS-4 160 11 stron.

IRIS-4 160
Quick Installation and
Maintenance Guide
Once the smartphone, tablet or laptop's Wi-Fi
connects to this network, you will need to enter the
password; check installation notes to see if this has
been changed, the default password is 'password' all
lower case .
Note: If engineers have never used/connected to an
IRIS-4 160 before it may be necessary to download/
install some application software to connect via
the Wi-Fi Web browser, please refer to Section 6.9
"Configuration".
Enter the installer code (should be noted somewhere,
possibly installation notes) and then click Logon .
Engineers will now be in the Main Menu and can
perform the following checks:
16
7.1. Confirm Current Status
Green SYS LED status is being reported ok go
straight to Section 7 . 2 "Checking battery status" .
Red SYS LED indicates a trouble reported go to the
option for "Trouble report" .
Check the reported system troubles via the
"Trouble report" menu . Please refer to the IRIS-4 160
Engineering Manual for more details available from
http://www . a ddsecure . c om .

7.2. Checking Battery Status

The IRIS-4 160 dialler will indicate any issues with
the batteries . Engineers can check the current battery
status via the "Battery Status" option and confirm
that the Health Status is showing as "Good" before
leaving site .

7.3. Replacing Batteries

If batteries fitted for backup purpose replaced them
every two years .
7.4. Check Software Version/Reflash
Go to the settings menu and then select "Latest
software?" this will then check with the AddSecure
Reflash server if there is a later version available .
If a later version is available, the engineer will see the
option to press the reflash button .
On first entry to the reflash option, which could be
during installation or maintenance, the engineer need
to change the password as required for EN50136-2
compliance . Please record the password on the instal-
lation documentation .
The reflash will take up to 15 minutes if via
4G/3G/2G and approximately 2 minutes with the
Ethernet connection . Once completed the dialler will
reboot and switch to the new software .
Note: All configurations for the IRIS-4 160 dialler
are stored and there is no need to reconfigure.

7.5. Communication Path Checks

The engineers can test the communication paths for
both polling and alarm communications using the
'Connection Test' option in the Main Menu . This
will perform communication path checks for each
path configured . Please refer to the IRIS-4 160
Engineer Manual for more detail available from
http://www . a ddsecure . c om .
IRIS-4 160
7.6. test alarm Panel alarms and
Communication to Monitoring Centre
Depending on the monitoring centre, engineers will
now be required to perform alarm test and possibly
other tests to the Monitoring Centre . Before leaving
site, the engineer should obtain confirmation from
the Monitoring Centre that all is working correctly .
17