Shipping temperature: -20°C to 60°C
Storage humidity:
Shipping humidity:
Altitude
Units tested at an altitude up to 12,000 feet must operate at normal conditions without exhibiting abnormal
behavior such as arcing or shutdown.
Operating altitude:
Shipping altitude:
Storage altitude:

Vibration Test

The packaged display shall be capable of passing sinusoidal vibration test as specified in follows.
1. Test condition as below:
a. Package sinusoidal vibration 7Hz, 1.05G acceleration, 20min/axe, 3axes
b. Random vibration, 10-500 Hz, 1.47G RMS
2. The unit under test shall be run for a duration of 30 minute in each of following orientations :
a. Top and bottom side ( z axis ).
b. Left and right side ( x axis ).
c. Front and rear side ( y axis ).
The unit shall suffer no visible cosmetic damage and should operate no degradation indisplay quality after
test.
Additionally, prior to production and prior to implementation of any design or manufacturing change that
Chapter1
10 % to 90 % ( non-condensing )
10 % to 90 % ( non-condensing )
0 to 12,000 feet
0 to 40,000 feet
0 to 40,000 feet
13