Caviblaster 1228-G Instrukcja obsługi i konserwacji - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Myjka ciśnieniowa Caviblaster 1228-G. Caviblaster 1228-G 11 stron.
WARNING:
Although the CaviBlaster
submerged in water, the system generates a high-
pressure (up to 2,200-psi) water stream, which can cause
injury when the gun is out of the water. ALWAYS keep
the gun submerged when the pressure pump is engaged.
Operating the CaviBlaster
1. When the diver is ready to commence cleaning operations, ensure that the gun is submerged
in water. Then move the throttle lever up to adjust the engine RPM to "MAX" (Figure 18).
Ensure that the power unit operator and other persons working in the vicinity of the power
unit wear appropriate hearing protection when the engine is
wearing a helmet, hearing protection is recommended. CaviDyne
Proplugs" vented earplugs or equivalent for diver hearing protection.
2. Activate the cleaning cavitation stream by squeezing the trigger to the open or "ON" position
(Figure 19).
3.
The most efficient operating technique is to hold the gun 2-3 inches away from the surface to
be cleaned and at a 25 to 45 degree angle to the surface being cleaned (Figure 19).
the gun closer than 2-3 inches from the surface being cleaned will not allow for efficient
cavitation performance and will degrade the cleaning capability of the system.
4.
Wear neoprene or rubber gloves to protect the hands and follow all safety regulations that
may be applicable to the work being performed.
Figure 19
®
system:
6
®
system is safe to use when
running. If the diver is not
recommends "Doc's
TM
Placing