DataComm Electronics 4x6 Phone Module with
Step 1
 Align the mounting pins with holes in the back of the HCC panel and lock
module into place.
 Pull the Cat 5 or higher rated cables into the HCC panel from one of the
side knockouts.
 Install Cat 5 or higher rated cables from each location in the house to the
8-port passive data module. Match the color-coding of the wires to the
colors on the 110 IDC connectors.
 The wires should be punched down, using an industry standard punch-
down tool, to the 110 IDC connectors following the T568A wiring
configuration as shown below.
Step 2 Telephone
 Pull the telephone wires into the HCC panel from one of the side
knockouts.
 Install the cable from the telephone company demarcation point to the
110 IDC marked from Telco.
 Install the twisted pair cables from each location in the house to the
remaining 110 IDC connectors. Match the color-coding of the wires to the
colors on the 110 IDC connectors.
 The wires should be punched down, using an industry standard punch-
down tool, to the 110 IDC connectors following the T568A wiring
configuration as shown below.
 Line 1 is Blue, Line 2 is Orange, Line 3 is Green and Line 4 is Brown.
 A RJ31X port is provided for line 1 seizure by security system.
INSTRUCTIONS ARE CONTINUED ON THE BACK SIDE OF THIS PAGE
Instruction / Installation Sheet
4 Port Passive Data 70-0023
White / Blue
Blue
White / Orange
Orange
White / Green
Green
White / Brown
Brown
3/13/08