CB LUFTKLAPPEN –
HIGH-PERFORMANCE FLAPS FOR NUMEROUS APPLICATIONS
Air ventilation channel, warm air channel, exhaust hoods, living space ventilation, basement ventilation, garret ventilation, cen-
tral heating room ventilation - combustion air supply for freestanding stoves.
SCOPE OF DELIVERY
• CB double flap module • PVC pipe for wall extender • outdoor ventilation grill stainless steel (for assembling outside wall)
shaft | spindle | motor-driven
ASSEMBLY INSTRUCTION – CB LUFTKLAPPEN
Recommended tools (for assembly in the wall): • core drill (ø 180 – 200 mm)
• saw/flex for PVC
• Phillips screwdriver
• silicon cartridge gun with insulation material
1. Unpack
Because of transport reasons the flap module is set in the pipe.
During the installation please gather the flap module from the PVC
pipe.
Attention:
the double flap is installed very tight in the PVC
pipe (double silicon sealing). In order to remove please turn the
double flap module slowly out of the pipe. Please do not cant!
2. Core drill hole (installation in the wall)
Do the core drilling at the defined place.
Hint:
Use a core drilling crown with ø 200mm – you will receive en-
ough space in order to isolate and fix the pipe in the wall.
3. Measure the wall thickness
In order to get the length for the pipe, please measure the thickness
of the wall.
4. Cutting the PVC pipe
Buck the PVC pipe with a straight cut.
Hint:
Cut the PVC pipe 1cm shorter than the wall thickness.
5. Fixing the PVC pipe
Use mineral wool and a tubular level in order to fix the PVC pipe tight
and centric in the borehole.
6. Installation of the outdoor ventilation grill
(installation in an outdoor wall)
Screw off the mask of the outdoor ventilation grill and remove the
insect net. Put in the installation frame of the outdoor ventilation
grill into the PVC pipe and mark the four boreholes on the wall. Re-
move the installation frame and do the drilling with a 6mm driller.
Put in the dowel pins and fix the installation frame. Please seal the
installation frame completely with insulating material (sealing bet-
ween wall and installation frame – also see picture), put in the net
and screw on the mask (when the insulating material has hardened).
• adapter for four corned
• drill machine
• folding rule
• rock drill 6mm
• tubular level
If you use the combustion air system on inside walls or on air ven-
tilation channels etc. the outdoor ventilation grill and / or the PVC
pipe is not necessary. Those components belong to the scope of de-
livery and cannot be passed back or credited.
7. Air flap module
Please set in the air flap module into the PVC pipe (drawing below
shows the double flap module).
Hint:
tag a silicone glue dot on the back of the stainless steel dead
stop (four pieces) an set in the air flap module into the PVC pipe (see
figure; position of the glue dots shown with arrows).
8. Adjustment
Afterwards adjust the air flap module even with the wall.
SAFETY INSTRUCTIONS / SAFETY NOTICE
The legal building requirements in the country/state and area of application must be followed during installation of
the air flaps! Please refer to the relevant authority for further clarification.
Use of the supplied outer grille (mounting in external
walls) at ground level: Beware that the cross-section may
be reduced by falling leaves or snow.
The flap modules may not be used in conditions excee-
ding 50 degrees centigrade.
Cables (electrical or other) should not be laid through the
flap module.
The correct functionality of the module should be che-
cked be fore installation.
When using an extension grip, it must be ensured that
movement of the grip and the function of the flap module
operate in parallel.
When using a motorised flap control mechanism, care
must be taken to ensure the correct power transmission
and safety functionality.
Aerodynamic resistance from the ventilation flaps or the
construction of the outer grille must be considered.
For many applications we recommend removing the flap grip after flap operation in order to ensure that unqualified
persons (children etc.) cannot operate it and thus impair or prevent its function.
The CB-tec GmbH disclaims all warranties or claims relating to incorrect or unlawfully installed flaps.
CB-tec GmbH
Behaimweg 2
D - 87781 Ungerhausen
When using as a combustion air duct/combustion air ope-
ning, the legal and particularly building/fire regulations in
the relevant country or area of application must be taken into
account! Information regarding how the combustion air duct/
combustion air opening must be constructed can usually be
obtained from the relevant authority or in many countries, the
responsible chimney sweep. Some countries/areas have le-
gal requirements that forbid closing or blocking of combusti-
on air ducts/combustion air openings in the case that no ad-
ditional safety features ((motorised flap control mechanism,
second parallel air duct from the installation room (regulati-
on: air flap for outdoor air closed - combustion air supply via
room air) etc) are provided, so that fireplaces/heating appli-
ances can only be used with an open shutter.
Tel.: +49 - (0) 83 31 - 49 86 6 - 0
Fax: +49 - (0) 83 31 - 49 86 6 - 19
www.cb-tec.de