Electrical Connections
25-pin connector
1
Shield
earth ground
2
TX
transmit data
3
RX
receive data
4
RTS
request to send
5
CTS
clear to send
6
nc
not connected
7
SGND
signal ground
8
EXT BEEPER
external beeper connection
9
VCC+
+5Vdc
10
nc
not connected
11
OUT+
See Figure 1
12
OUT-
13
VCC+
+5Vdc
14
nc
not connected
15
nc
not connected
16
nc
not connected
17
nc
not connected
18
EXT TRIG+
See Figure 2
19
EXT TRIG-
20
DATAIN_WAND
21
DATAOUT
22
OUT-
23
CLKIN
24
CLKOUT
25
GND
power ground
Led Status
ON = Power ON
POWER ON
OFF = Power OFF
ON = Good Read
GOOD READ
(the LED will remain ON until status changes)
OFF = No Read
68.6
[2.70]
mm
[in.]
TC1100
USER INTERFACE
Vext 40 Vdc max
11
OUT +
12
OUT -
Figure 1 - Output Connection (Good Read). Example NPN
Return to RS232 Interface
Ì$+CP0$-$Î
For WEDGE Users
Physical Dimensions
Width
70.7 mm
2.78 inches
Length
68.6 mm
2.70 inches
Height
30.5 mm
1.20 inches
24
[0.94]
31.6
10.4
[0.41]
[1.25]
Optical Axis
TC1100
Vext
30 Vdc max.
EXTERNAL TRIGGER
+ 5V
18
EXT TRIG+
V
19
EXT TRIG-
Signal
Input NPN command using external power
TC1100
EXTERNAL TRIGGER
13
Vcc 5Vdc
V
+ 5V
18
EXT TRIG+
19
EXT TRIG-
Signal
25 GND
Ground
Input NPN command using TC1100 power
Figure 2 - Trigger Connections
Basic Commands for TC1100
The TC1100 default configuration can be changed by receiving commands through the RS232
Interface. The command syntax is given below with an example.
Command syntax
$+ Command(s) $- <CR> the new setting will be definitive (stored in FLASH EPROM)
Example:
Multiple command programming sequence:
$+
BK0
CD7
Enter configuration environment
Serial On-Line Operating Mode
Baud Rate = 19200
Commands:
OPERATING MODES
On-line
BK1
Serial On-line
BK0
Automatic
BK3
Automatic / Lighting System Standby
BK2
To enter in Test mode
#+DStat1<CR> (does not require $+ or $-)
To exit Test mode
#+DStat0<CR> (does not require $+ or $-)
GENERAL FEATURES
RS232 interface selection
CP0
RS232 Baud Rate
CD0
for 150 Baud up to CD8 for 38400 Baud
WEDGE AT
CP500
WEDGE Notebook
CP505
Keyboard Nationality
FJ7
Belgian
FJ4
English
FJ2
French
FJ3
German
CCD Scan Rate
BT0
67 scans/sec
BT1
135 scans/sec
BT2
270 scans/sec
Puzzle Solver
AU1
enable
Ink Spread
AX1
enable
Decoding safety
ED0
1 read
ED1
2 reads
To restore the default configuration
$+$*<CR> (does not require $-)
To get configuration from the scanner
$+$&<CR> (does not require $-)
Vext
30 Vdc max.
TC1100
EXTERNAL TRIGGER
V
+ 5V
18
EXT TRIG+
19
EXT TRIG-
Ground
Input PNP command using external power
TC1100
EXTERNAL TRIGGER
Vcc 5Vdc
13
V
+ 5V
Signal
18
EXT TRIG+
19
EXT TRIG-
25
GND
Ground
Input PNP command using TC1100 power
AC410132
$-
CR
Carriage return character (0D Hex.)
Exit and save new configuration
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
FJ1
Italian
FJ6
Spanish
FJ5
Swedish
FJ0
USA
AU0
disable
AX0
disable
ED2
3 reads
ED3
4 reads
Signal