Device Specific Parameters
Index
Parameter
Subindex
Lenght
Value/Range
(dec)
Object Name
(offset)
0 = no DELAY (default U03, T53, B53)
0x1 = Delay ON/OFF
1 octet
1(8)
0x2 = Delay ON
0x4 = Delay OFF (default W03)
0x0048 (72)
Delay Settings
0...(2^8)-1
1 octet
2(0)
20 (default)
0x01 = PNP (default)
0x02 = NPN
1 octet
1(8)
0x03 = Push Pull
0x00B4 (180)
Output type
0x01 = PNP (default)
0x02 = NPN
1 octet
2(0)
0x03 = Push Pull
0x04 = Input
0x0 = All enabled (default)
0x1 = Push Button disabled
0x0058 (88)
Keylock
1 octet
0x2 = Trimmer disabled
0x3 = All disabled
Standard Command
Index (dec) Command Name
Lenght
Value (dec)
0x0002 (2)
SP1 Single Value Teach
1 octet
0x41 (65)
0x0002 (2)
SP1 Teach TP1
1 octet
0x43 (67)
0x0002 (2)
SP1 Teach TP2
1 octet
0x44 (68)
Teach Dynamic /
0x0002 (2)
1 octet
0x4B (75)
Max. Sensitivity
0x0002 (2)
Teach Dynamic End
1 octet
0x4F (79)
0x0002 (2)
Restore Factory Settings
1 octet
0x82 (130)
0x0002 (2)
Confirm Maintenance
1 octet
0xA5 (165)
0x0002 (2)
Disable/enable emission
1 octet
0xB0 (176)
0x0002 (2)
Start / Stop Ping
1 octet
0xAF (175)
Events
Event code (dec)
Event name
0x4220 (16928)
Temperature underrun
0x4210 (16912)
Temperature overrun
0x5100 (20736)
General power supply fault
0x7710 (30480)
Short circuit - Check installation
0x8C40 (35904)
Maintenance required - Lens cleaning
0x8CA0 (36900)
Laser fault
Description
Select Delay mode (OFF)
Delay value =
Delay [ms]
Output type of C/Q pin when in SIO mode
Output type of DO pin
Keylock
Description
Reflector Acquisition (B53, T53) / EASY Acquisition (U03)
Acquisition FINE: Mark Detection (W03, U03) (refer to User's Manual)
Acquisition FINE: Background Detection (W03, U03) (refer to User's Manual)
Dynamic acquisition (W03) / Max. Sensitivity (T53, B53, U03)
Exit from Dynamic Detection (W03)
Restore factory settings (Device Access Locks, Application Specific Tag, Function Tag, Location Tag, SSC1 Param, SSC1 Config, SSC2 Param, SSC1 Config,
Delay Settings, Sensitivity selection, Output type, RGB selection (W03), Frequency Selection (U03), Switch counter settings, Switch counter values, Keylock)
Reset Maintenance parameters (Operating Hours Maintenance, Minimum device temperature since powerup, Maximum device temperature since powerup,
Device Status, Detailed Device Status)
Toggle emission (enable / disable emission)
Feature to identify the sensor by yellow LED blinking
Event mode
Event type
Appears / Disappears
Warning
Appears / Disappears
Warning
Appears / Disappears
Error
Appears / Disappears
Error
Appears / Disappears
Notification
Appears / Disappears
Error
Data Type
Access*
Remark
UIntegerT
R/W
Saved in non-volatile memory.
Max. Value 255 ms
UIntegerT
R/W
UIntegerT
R/W
Saved in non-volatile memory
UIntegerT
R/W
UInterT
R/W
Saved in non-volatile memory
Access*
WO
WO
WO
WO
WO
WO
WO
WO
WO
Device status
Remarks
Out of specification
Out of specification
Failure
Failure
Maintenance required
B53 only
Failure
B53 only
*RO = read only, WO = write only, R/W = read/write