Island Clean Air Filters
Each ICA filter has been engineered to provide maximum filtration with calibrated
velocities to capture harmful airborne particulates. Using non-ICA branded filters in
the Duster 3000 Downdraft will: not seal properly, impede airflow, jeopardize
system, and void the warranty.
*** Proper Cleaning & Maintenance Will Prolong Filter Life ***
Stage 1: Green Pre-Filter Pad (Part #11703)
Filters dust and paint overspray.
Clean daily or weekly. Do not pressure wash.
Vacuum the front of the green pad. Remove from intake filter and blow with
compressed air.
It has an approximate life of 2-3 months.
Stage 2: Pleated Intake Filter (Part #11205)
Filters dust and paint overspray.
Clean daily or weekly. Do not pressure wash.
Remove from machine and remove green pad. Blow yellow pleated side with
compressed air and vacuum white pad.
It has an approximate life of 6-9 months.
Stage 3: Activated Carbon Filter (Part #11209)
Absorbs VOCs, fumes, and odors.
Not cleanable. To improve fume absorption efficiency, shake monthly.
Replace when it weighs over 15lbs. Typical life of 9-12 months.
Stage 4: Viledon Top Pocket Filter (Part #11207)
Filters smaller particles down to 3 microns.
Not cleanable. As it gets dirty, it will slowly change color from white to dark gray.
With proper maintenance of the other three stages, this filter may last up to 18-24
months.
Accessing the Viledon Top Pocket Filter
Turn off the unit and unplug from electrical outlet.
Remove plenum from Lexan shroud.
Hang the plenum on gray support rod.
Unlatch the four quick release latches and lift the Lexan
shroud off.
The Viledon is now accessible and can be replaced.
When installed properly, all five pockets of the Viledon
should be visible from the front of the unit and be inflated
and vertically aligned.
When reinstalling the Lexan shroud, ensure that the
pockets of the Viledon are not pinched between the body
and shroud.