Dustless 16003 Instrukcja obsługi - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Odkurzacz Dustless 16003. Dustless 16003 9 stron. 16 gallon
Również dla Dustless 16003: Instrukcja obsługi (4 strony)
Problem
Cleaner won't run
Loss of suction
Using gitator Rod
does not clean filters
(Non-HEP vacuum)
Filters get wet
Unit blows dust
Problem
Tool will not start when
plugged into vacuum
Vacuum will not start
when the tool starts
Wireless module will
not start vacuum
Wireless module lights are not
blinking when tool activates
CCESSORIES
(not to scale)
25'Hose & 2 Cuffs
Set #14291
Dustie
Numerous item #'s available,
see our web page at
www.dustlesstechnologies.com
TROUBLE SHOOTING GUIDE
Possible Cause
Not firmly plugged in
No voltage in wall plug
Blown fuse/tripped breaker
Obstruction in hose in place
Coated primary filter
Coated secondary filter
Hole/split in hose
Tank is full
Unit tipped over
Micro Prefilter is full
Too much debris around the primary filter
Both filters plugged
Drain cap not sealed
O-ring on drain cap not in place
Debris not emptied from tank before use
Filters not in place
Hole in filter/s
Secondary filter not in place
Primary filter not in place
TOOLSYNC TROUBLE SHOOTING GUIDE
Possible Cause
Switch in wrong position
Tool draws too little current
Tool draws too much current
Module has not been trained for this vacuum
Tool drawing too little current
Drawing plenty of current but still not transmitting
V IL BLE
HEP Filter
#13201 for #16006 and
16011 Vacuums HEP
Vacuum only
BitBuddie
Numerous item #'s available,
Filter Package
see our web page at
#13001
www.dustlesstechnologies.com
Possible Solution
Plug in unit firmly
Check fuse or breaker
Replace fuse/reset breaker
Clean obstruction
Clean Filter with cleaning agitator rod
Remove primary filter and replace/launder both filters
Inspect and replace hose
Empty tank of waste
Put unit in upright position
Dispose of filter and debris.
Empty debris from intermediate cover and tank
Replace or launder both filters.
Tighten drain cap
Replace o-ring
Empty tank and intermediate cover of waste
** lways dry filters thoroughly before continued use
Check filters
Check/replace filters
Check secondary filter
Check primary filter
Possible Solution
Switch must be in II or auto-start position
Make contract with work surface to draw more current
Use a remote start module
Go through training procedure
Make contract with work surface to draw more current
Try another tool, if unsuccessful contact customer support
Turbo Carpet
Head #13241
2 Cuff daptor
Numerous item #'s available,
ChipBuddie
Package #14191
#61001
www.dustlesstechnologies.com
ToolSync Reset/Training
Wire Brush Tool
#14112
Micro
Prefilter Bag
#13141
Set of 2
Round Wire Brush
Tool #14113
DustBuddie
see our web page at
Wireless Tool Start Adapter
Model D5250
Made in USA
www.dustlesstechnologies.com
ToolSync Electric dapter
plug #D5260
#D5250
Pole Sander
#50001
ToolSync ir dapter
#D5255
7