Dataprobe COE-8I Instalacja sprzętu - Strona 5
Przeglądaj online lub pobierz pdf Instalacja sprzętu dla Sprzęt sieciowy Dataprobe COE-8I. Dataprobe COE-8I 7 stron. Contact closure over ethernet
COE-8
Setup
The Setup button from the Home page provides access to all the configuration of the COE-8. The
Setup area is divided into several pages:
Device Page:
Basic setup of the COE-8, IP address and TCP/IP settings
Name
IP Address
Set the IP Address manually in the Static Mode (see below)
IP Modes
Set the method to configure the IP address. See section above for details.
§
Static: Manually entered IP address information
§
DHCP: IP address obtained upon power up from DHCP server.
Port Settings The IP Setup page also allows for changing of the port assignment for both the Control
communication and web page access. Dataprobe recommends changing the Web port for units that
will be connected to the Internet. This will minimize the number of hacker attacks that the COE-8 will be
subject to.
The Control Port for both the COE-8I and all COE-8Os that receive status from it must be set the
same.
If a port other than the default Port 80 is used for web browser access, that port must specifically be
used in the URL when accessing the COE-8. For example, if the Web Port is changed to 9090 then the
URL for the unit would be http://192.168.1.254:9090
Receivers (COE-8I Only)
Transmission Frequency
This sets the frequency that the COE-8I transmits its status to the receivers. When set to 0,
transmission will only occur upon change of status.
Receiver IP Address
information set to them. If you wish to send the same input channel status to two different channels on
any one COE-8O, then that IP address must be entered twice in the table.
Inputs (COE-8I Only)
The COE-8I can send individual input status to multiple COE-8O receivers, or other IP address. This
page provides for selecting which output of the COE-8Os will be operated by each input of the COE-8I.
Select the Input from the drop down box, then configure the Name for that input, along with the channel
of each COE-8O unit to receive the status. Click Apply after each channel is configured.
Use Output 0 if no output of a given COE-8O is to be used for that channel. Configure each of the 8
inputs as necessary.
Assign a name up to 20 characters to help identify the COE-8
0 to 9999 seconds
Set up to 32 IP addresses of the COE-8O units that will have input status
Page 5