Aussie Pumps AB Scud 40 Instrukcja obsługi - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Aussie Pumps AB Scud 40. Aussie Pumps AB Scud 40 16 stron. Stainless steel frames, 3,000/4,000 psi
Również dla Aussie Pumps AB Scud 40: Instrukcja obsługi (16 strony)
Feb 2019
C.
Before starting the machine
OPERATE IN WELL VENTILATED AREAS ONLY.
1. Ensure machine is level
2. Turn on water supply.
3. Pull gun trigger until water starts to flow in a
steady steam then release trigger.
D.
Starting the engine
(refer to Honda engine manual for more details)
1. Ensure fuel valve is open
2. Move the choke on the engine to the closed
position . If engine is warm, move choke half-way.
3. Turn engine ON/OFF switch to ON
4. Hold the gun trigger on.
5. Start engine, pull the recoil starter grip lightly until
resistance is felt, then pull briskly.
Aussie Safety Protection Kit
Unloader - factory set,
DO NOT adjust
Detergent injector ...
attach poly tube with strainer
HP hose connection
Aussie AB Direct Drive Super Scud Series ... Operation & Maintenance Manual
UNLOADER SETTING
The high pressure unloader on the machine is factory set to
operate the pump at it's rated pressure.
DO NOT ADJUST. Tampering with the unloader will void
warranty and can be dangerous.
Throttle ... fully open
Choke ... closed position
Fuel value open
6. After engine starts, release the gun trigger and
slowly open the choke.
7. Warm up engine for 3 minutes without load.
Aussie Pumps
Safety valve
Thermal dump
Supply hose
connection
7