REGULATING PRESSURE.
This chapter concerns only
those models provided with
the "pressure regulating" de-
vice. The pressure regulator,
fig. 10, allows the operator to
adjust the working pressure.
When knob C is turned
an anti-clockwise direction
(B) (minimum), the working
pressure is reduced.
Use the steam nozzle (supplied as an accessory).
Turn the thermostat knob "B" (fig. 8) to steam position to obtain
an increase in the temperature of the water at delivery.
At work temperatures higher than 95°C (203°F), the work
pressure must be < 32 bar (460 PSI).
!
Danger
During use with boiling water, "Steam Phase", keep away
from the openings for fumes discharge (risk of burning).
When you have finished using the "Steam Phase", turn the
thermostat knob "B" to position "0" (fig. 8) and let the ma-
chine cool down for about 3 minutes with the gun turned on.
in
FIG. 10
MAINTENANCE
ONLY THE OPERATIONS AUTHORIZED IN THIS
INSTRUCTION MANUAL MAY BE CARRIED OUT BY
ALL OTHER OPERATIONS ARE FORBIDDEN.
!
Danger
For maintenance of the boiler, high pressure pump, the electrical
parts and all parts with a safety function, you must apply to our
Technical service centre.
The manufacturer is not liable in case of tampering, changes, in-
correct repairs or maintenance carried out on the machine by a
third person not provided with the manufacturer's authorization.
All documents pertaining to the repair and planned service
interventions, as well as any certificates concerning the device
installation according to the laws in force (in compliance with the
provisions of the IEC 60364-1 standard) must be kept carefully
by the user, together with the Instructions Manual.
Periodically, at least once a year, have the safety devices and
the rated values checked at one of our technical service centres.
Particularly, as for the hot water high pressure cleaner, which is
factory set, the exhaust system must be checked.
The rating done by the manufacturer determines a production of
exhaust gases with a CO content lower than 0,04% and a smoke
content corresponding to a smoke point nr.2 Shell-Bacharach
according to the laws in force.
!
Danger
Disconnect the water cleaner from the mains electricity supply
via the omnipolar switch or by unplugging the plug from the
socket and close the water supply tap (see chapters on connec-
ting to the electricity and water
maintenance jobs. Once maintenance has been completed,
ensure that the closing panels have been correctly reassembled
and anchored with the screws provided before reconnecting the
cleaner to the mains.
Failure to do so may cause a risk of electric shock.
-
-
THE USER.
mains) before carrying out any