Cooke & Lewis 3663602842071 Podręcznik - Strona 13
Przeglądaj online lub pobierz pdf Podręcznik dla Hob Cooke & Lewis 3663602842071. Cooke & Lewis 3663602842071 20 stron.
Use
Before you start
Switch on the appliance at the switched fused connection unit. The appliance is ready for use.
WARNING: Read the instructions before using the appliance.
Functions and settings
• Flame safety device (FSD): Stops the gas supply to the gas hob when the flame goes out.
• Auto ignition.
Injector Table
Gas Category UK & IR
II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
Type of
Type of
gas used
burner
Auxiliary
NATURAL GAS
Semi Rapid
(Methane)
Rapid
G20
Triple Crown
Auxiliary
LIQUEFIED
Semi Rapid
PETROLEUM GAS
(Butane)
Rapid
G30
Triple Crown
Auxiliary
LIQUEFIED
Semi Rapid
PETROLEUM GAS
(Propane)
Rapid
G31
Triple Crown
TRAG10580 - 200000004 - 5 Burner Gas v3b Rv2.indd 13
Injector
Rated
marking
thermal
flow rate
kW
0.72mm
0.95
0.97mm
1.75
1.15mm
2.90
1.50mm
3.80
0.50mm
0.90
0.65mm
1.65
0.85mm
2.90
1.01mm
4.00
0.50mm
0.90
0.65mm
1.65
0.85mm
2.90
1.01mm
4.00
Rated
Reduced
consumption
heat
capacity
kW
91 lt/h
0.28
167 lt/h
0.45
276 lt/h
0.75
362 lt/h
1.35
65 g/h
0.25
120 g/h
0.40
211 g/h
0.80
291 g/h
1.40
64 g/h
0.25
118 g/h
0.40
207 g/h
0.80
286 g/h
1.40
13
Gas Pressure
rating (mbar)
20
28-30
37
13/06/2017 16:06