Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Wzmacniacz AUSTRALIAN MONITOR AMB1200. AUSTRALIAN MONITOR AMB1200 13 stron. Amb series
Model
Topology
Channels
Power Output
Single Channel 4Ω
Single Channel 8Ω
Mono 4Ω (Both Driven)
Mono 8Ω (Both Driven)
Bridged 8Ω
Maximum Output Level
33.01dBu (34.64Vrms)
Frequency Response
Signal to Noise Ratio
THD+N. 4Ω, 8Ω. 1kHz
Channel Separation
≥ 65 dB ( for ≤ 1KHz )
(crosstalk)
≥ 50 dB ( for > 1KHz )
Damping Factor
Input Connectors
2 Female XLR, 2 Male XLR
Input Impedance
Output Impedance
Input Sensitivity
1.23Vrms (+4.0dBu)
Input CMRR
Output Connectors
2 x Neutrik speakON
LED Status
Gain, Stereo/Bridged/
User Controls
Attenuation Control
AC Input
230Vac, 50-60Hz
AC Power Factor
AC Connector
Maximum Inrush Current
Overload Protection
Temperature, Current Limit
AC Mains Fuse
4A resettable circuit breaker 7A resettable circuit breaker 10A resettable circuit breaker
AMB SERIES AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL
AMB 600
AMB 1200
Class-AB
2
400W
250W
300W
200W
600W
36.02dBu (48.99Vrms)
20Hz - 20kHz
20Hz - 20kHz
> 100dBr
> 100dBA
< 0.06%
≥ 65 dB ( for ≤ 1KHz )
≥ 50 dB ( for > 1KHz )
≥ 200
2 Female XLR, 2 Male XLR
20kΩ
40mΩ
1.23Vrms (+4.0dBu)
≥ 55dB
4 x Binding Posts
4 x Binding Posts
2 x Neutrik speakON
Signal, Clip, Fault
Signal, Clip, Fault
Gain, Stereo/Bridged/
Mono switch
Mono switch
-24dB Log scale
-24dB Log scale
230Vac, 50-60Hz
0.85
IEC 60320-C14
IEC 60320-C14
21A
Temperature, Current Limit
AMB 1600
Class-AB
Class-AB
2
760W
900W
450W
550W
600W
800W
380W
500W
1200W
1600W
48.06dBu (56.56Vrms)
20Hz - 20kHz
> 100dBr
< 0.06%
< 0.06%
≥ 65 dB ( for ≤ 1KHz )
≥ 50 dB ( for > 1KHz )
≥ 200
≥ 200
4 Female XLR, 2 Male XLR
20kΩ
20kΩ
40mΩ
40mΩ
1.23Vrms (+4.0dBu)
≥ 55dB
≥ 55dB
4 x Binding Posts
2 x Neutrik speakON
Signal, Clip, Fault
Gain, Stereo/Bridged/
Mono switch
-24dB Log scale
230Vac, 50-60Hz
0.84
0.81
IEC 60320-C14
35A
51.3A
Temperature, Current Limit
SPECIFICATIONS
Conditions/Comments
2
1kHz, 1%THD, ±50W
1kHz, 1%THD, ±50W
1kHz, 1%THD, ±50W
1kHz, 1%THD, ±50W
1kHz, 1%THD, ±50W
20Hz - 20kHz, <1%THD
3dB below clipping, +0/-3dB
Max Output, 1kHz, 20kHz BW, A-Weighted
3dB below clipping, 1kHz. 20kHz BW,
Unity Gain, A-Weighted
20Hz - 20kHz, +4dBu, Adjacent Channels
20Hz - 1kHz, 8Ω
Balanced, line to line
±0.2V. Level control at maximum
20Hz - 20kHz
10-24 AWG Wire
21 step volume control
±10%
Max Output, 1kHz
253VAC, 53Hz
Specifications continued over page
PAGE 11