leaning the door glass:
1.)
Lock sliding mechanism.
1.) + 2.) Loosen the left and right bolt on the top of the sliding door. If you have a hinged model, just open
the door. 3.)
Protect the fireplace bench or floor before the cleaning.
Spray glass with glass cleaning liquid and leave to react.
Remove dissolved soot with an absorbent cloth or kitchen roll.
Finally close door properly and lock the swinging latches again.

16. behaviour in case of a chimney fire

If prohibited or moist fuel is used, it may lead to chimney sooting and thus lead to a chimney fire.
Correct behaviour in case of a chimney fire:
call the fire brigade and the local chimney sweep.
close the combustion air inlets!
enable free access to the cleaning apertures of the chimney (e.g. cellar or attic)!
remove alle flammable materials near the chimney.
Before operating the firplace again after a chimney fire, please inform your local chimney sweep and
let him check the chimney system for possible damages!

17. combustion chamber refractory lining

The combustion chamber lining is made of Keramott. This is a top-quality material with special features
for a better combustion and a very appealing visual effect. The Keramott parts may show fine crackings
during or after operation, which have however no influence on the function – a replacement of such parts
is thus not necessary.
18. sliding door – guiding rails
Both guiding rails should be lubricated at least once a year. To do so please lift the door
up into the highest position and thinly apply the high temperature lubricant on the
marked area on the guiding rails (Fin Grease, -30 °C to 220 °C).

19. what to do if, ...?

... if the fire smoulders or goes out by itself?
Is the throttle valve open?
Is the deflection damper of the heat exchanger in the right position?
Is the combustion air flap open (+)?
2.)
Unlock swinging latch.
8
3.)
Swing open the door.