Gage Bilt GB55B Oryginalna instrukcja obsługi - Strona 11

Przeglądaj online lub pobierz pdf Oryginalna instrukcja obsługi dla Narzędzia Gage Bilt GB55B. Gage Bilt GB55B 16 stron. Pneumatic installation tool

Providing all maintenance conditions have been met, follow this systematic approach to diagnosis.
1. MORE THAN ONE PULL IS REQUIRED TO BREAK FASTENER WHEN THE ACTUATOR ASSEMBLY (510127) IS DEPRESSED.
a) Jaws are stripped or packed with chips. Clean or replace.
b) Incorrect nose tip.
2. FASTENER STEM JAMMED IN NOSE ASSEMBLY.
a) Nose assembly components require service.
and disassemble. Replace worn or broken parts. Clean the surface the jaws ride on.
b) Stems lodged side by side in the follower. Disassemble, remove stems, and reassemble. See nose assembly instructions
for 3/32ø (pg. 8). (See proper nose assembly data sheet for detailed instructions).
c) Incorrect follower.
GB55B S/N: 1014 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.

TROUBLESHOOTING

DISCONNECT AIR FROM
11
TOOL, remove the nose assembly from the tool
Rev. 1/23