Dawnco series 3000 Instrukcja obsługi - Strona 4
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przekaźniki Dawnco series 3000. Dawnco series 3000 9 stron. Audio/video - if/rf relay panel
Mounting:
The 3000R-165 requires a minimum of 1.75 vertical inches of space in a standard 19" wide
EIA equipment rack. Slide the unit into the rack frame and secure it, using the 3000R/22M
mounting hardware supplied with the unit.
Connections:
1. The Video (or IF/RF) switches are mechanical relays, and connections to them
are made through 75
cable for the default signal to the NC (normally closed or primary) connector. Connect
your cable for your alternate signal - which you will substitute for the default
signal - to the NO (normally open or secondary) connector. Connect the cable to your
modulator or other destination to the COM (common or output) connector.
These connectors will switch either video signals, or may alternately be used to
switch high frequency signals, such as IF or RF. The frequencies useable are
shown on the frequency response charts included.
Of course, both inputs must be the same type of signal.
It is also permissible to use some relay sets for baseband video and some
for high frequency, since all switch modules are isolated.
2. If the signals being switched are baseband video, with audio following, connect the
audio signals to screw terminals of the same switch group, ensuring that the left and
right channels for the default audio are connected to the L NC + and -, and the
R NC + and -, and the signals for the alternate signal are attached to the L NO
+ and - and the R NO + and - connectors. The L OUT + and - and the R OUT
+ and - are routed to the modulator or other destination of the audio signals.
3. To actuate a relay section with a contact closure, connect the contacts
between each relay control input screw terminals (SW1–SW4) and ground (GND) screw
terminal. Refer to the rear panel connections illustration and the applications section of
this manual.
4. Connect the +12 VDC lead (white) from the power supply to the +12v terminal on the
rear panel, and the black lead to the GND terminal. Plug the power supply into a 90 -
264VAC power outlet, and the unit is ready to function.
5. If wiring balanced stereo audio (or balanced mono audio), and a tie point for the ground
wires is required, use the AUX2-COM and AUX1-COM terminals. These points are
floating if no connections are made to AUX2-NO and AUX2-NC and the AUX1-NC
points.
Operation
When the contact closure for the appropriate Relay Unit is closed, the output (Com)
connection is switched from the default input (NC) to the alternate input (NO).
General Instructions
F connectors on the rear of the unit. Connect your
4