INSTALLING THE CONDENSER SET
Marking out the floor
■
Use the floor template as provided (or refer to fig. 3). Both, or either end of the con/set may be hard against
a wall or panel, but the back of the unit must have sufficient clearance to allow easy access to the line
valves (see fig. 4). Once a convenient position has been decided upon, place the template, side marked
"Inside Wall", hard against the inside skin of the van, and mark out the six 114 mm diameter (4
condenser air inlet holes, and the square compressor well hole (see fig. 3).
Note: Check to see if any structural floor members will interfere with any of these holes. It is essential that
the compressor well is unimpeded. The compressor feet project through the well by 4 to 5 mm, therefore
clearance of at least 8 mm must be maintained between the well and any floor members. Eg. Angles or
tubes. Lack of clearance will result in noise and vibration. See fig 5.
The air inlet holes will tolerate some obstruction.
However the total area must not be less than 75% of
the inlet holes in the chassis. DO NOT install fine
mesh (flywire) over the inlet holes.
We recommend that a hole saw be used to cut out the
six round holes. If a structural member is beneath,
then the complete cut out can be removed. The gap
between the top of the structural member and the
underside of the unit (i.e. the floor thickness) will
help in overcoming the restriction of the member.
Marking out the wall
■
Now mark out the hole in the wall for the condenser
discharge grille (see fig. 5).
Mark out the position and size of the air outlet hole,
from inside the van, using the floor as reference.
Pilot holes can be drilled at the four corners, and the
hole cut out from the outside. It is essential to frame
up this hole to give a firm seal to the air outlet from
the con/set and to stop any discharge air from
entering the wall space.
Positioning of the Con/set
■
Lay down a generous bead of silicone on the floor to
match the perimeter of the Con/set. Now, lift the Con/
set into position, and check that the compressor well
does not interfere and prevent the con/set from sitting
firmly on the floor.
Push the Con/set hard up against the wall.
It is vital that the Con/set seals hard against the
inside wall to ensure no hot air leakage during
operation.
To secure the Con/set in position, use the three hold
down clips provided (see fig. 4). These clip over the
edge of the chassis. At least one clip should be
installed on the back edge to ensure the good airseal
is maintained against the inside wall. Screw the clips
firmly to the floor.
Normally install condenser
set opposite to annexe
Clips
Figure 4
Figure 4a
Showing method for securing condenser set to floor with 3 clips
Figure 5
Cut out detail for
condenser
2
/
")
1
2
50
10
178
Comp.
180
well
107
237
372
Figure 3
Foot print
of condenser
265
390
Line
Valves