Install Appliance
Note: The appliance is heavy. It is advisable to install it
with a second person.
NOTICE
Before installing the appliance, be sure to verify the
cabinet dimensions and electrical connections.
Mount to Cabinet
1.
Push the appliance fully into the cabinet recess.
Do not kink or trap the connecting cable, or route it
over sharp edges.
2.
Remove the transportation lock from the door. Centre
the appliance.
There must be an air gap of
appliance and adjacent cabinets.
3.
Using a spirit level, adjust the appliance so that it is
perfectly level.
4.
Secure the appliance at the top on both sides using
into the two screws provided.
Electrical Installation
1.
Connect red wire from oven to red electrical supply
wire (hot wire).
2.
Connect black wire from oven to black electrical
supply wire (hot wire).
3.
Connect white wire from oven to white electrical
supply wire (neutral).
4.
Connect yellow/green ground oven wire to electrical
supply ground wire.
Attach flexible conduit to the junction box.
To facilitate serviceability, the flex conduit must not be
shortened and should be routed to allow for temporary
removal of the oven.
Connection to the home network (LAN)
This appliance is network-compatible and can be
connected to the home network using a LAN cable (LAN
cable not included). Before installation, plug the LAN
cable into the socket on the rear of the appliance and
secure it using the strain relief. Connect the LAN cable
to a network socket.
/
" (5 mm) between the
3
16
Check the Installation
9
WARNING
Before you plug in an electrical cord or turn on
power supply, make sure all controls are in the OFF
position.
Switch on the circuit breaker.
Verify that elements function properly.
Removal
1.
Disconnect the appliance from the power supply.
2.
Undo the fastening screws.
3.
Raise the appliance slightly and pull it out completely.
Preparing Kitchen Units
en-us