1) Insert an airline connection into the air inlet (7) using PTFE tape if required. Details of the air inlet thread
sizes can be found in the specification chart, See specifications. An airline with an internal diameter of
13mm minimum is recommended for optimum tool efficiency.
2) Fit the supplied handle (not required on the IP850) to the torque tool. Hand, arm, vibration (HAV) figures
are taken from a tool with a properly fitted handle.
Figure 1
3) Connect the tool to the Filter, regulator and lubricator unit ("FRL" (recommended)) ensuring that the oil
reservoir has sufficient airline oil and the drop rate is set to approx. 1-2 drops every few minutes. This rate
can be adjusted to suit the tooling size and the environment. More details on the FRL units can be found in
the operating instructions supplied with the FRL unit and also in the Hi-Force catalogue and online at
www.Hi-Force.com.
Airline connections should be secured by a whip prevention system to avoid injury due to
whipping, if a failed component occurred.
4) Without the tool connected to any application or socket, and the regulator set to zero, depress the trigger
(4) and gradually turn up the regulator allowing the tool to free speed until the required max is reached. If
there are any signs of air leaks, stop the tool, dis-charge any residual air in the system and investigate the
leak.
NOTE: If the tool is to be used in cold conditions, has been stored in a cold environment, or has not been
used for a long period of time. It is recommended to allow the tool free speed, without the tool connected to
any application or socket, to allow it to come up to temperature and prevent seizing due to the oil viscosity
thickening in the tool.
5) The regulator can be used to decrease the operating pressure if the tools max range is not required, this
will reduce both the energy used and the energy required by the operator. Noise (dB) levels will be lowered
and the tools longevity will be greatly increased.