Gaggenau VG 232 CA Instrukcja obsługi i montażu - Strona 14

Przeglądaj online lub pobierz pdf Instrukcja obsługi i montażu dla Płyta grzewcza Gaggenau VG 232 CA. Gaggenau VG 232 CA 20 stron. Gas cooker vg 232 ca operating and assembly instructions
Również dla Gaggenau VG 232 CA: Instrukcja obsługi i montażu (14 strony)

Gaggenau VG 232 CA Instrukcja obsługi i montażu

7. Assembly instructions

7.1 Important notes

Please observe the safety notes and the
important notes (Chapter 1).
The installing technician is responsible for
perfect functioning of the appliance at its installa-
tion location.
He must explain the operating principle to the user
with reference to the operating instructions and
must show how to switch of the electricity and gas
whenever required.
Caution:
Before connecting the appliance, please check
whether the local connection conditions such as
the gas type, gas pressure and mains voltage and
the appliance settings are correct. Refer to the
adhesive label on the gas connection or the rating
plate for the necessary information. This gas hob
conforms to the categories that are specified on the
rating plate. The rating plate can be found on the
appliance and additionally on the enclosed adden-
dum sheet. By replacing nozzles, it is possible to
set the appliance to any gas listed on the rating
plate.
If the data should not agree, the appliance must
be set to the required gas type and the available
pressure.
As this gas hob is not intended for connection to an
exhaust gas system, pay attention to the applicable
installation conditions.
Note on ventilation:
To ensure good combustion, the room in which this
appliance is installed must have a minimum volume
of 20 m
3
and a door that opens out to outdoors or a
window that can be opened.
The appliance may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures. The
rear wall must consist of non-combustible material.
A minimum distance of 150 mm (6") from heat-
sensitive items of furnishing or contact surfaces
(cupboard side panel) must be observed.
The hob conforms to appliance class 3 and must be
installed in the worktop as shown in the installation
sketch.
The distance between the suspended cupboard
and the worktop must be at least 600 mm (24").
Attention must be paid to the manufacturer's
specified safety clearance when a vapour extractor
is installed.
Wall trims must be heat-resistant, and the minimum
distance between the hob and the wall trim is at
least 35 mm (1
3
/
").
8
After unpacking, check the appliance for any
transportation damage and report this immediately
to the transportation company.
Technical modifications reserved.
13