DIGITAL INDICATOR SET-UP
Menu : Hold and Print buttons pressed at the same time then
C1 – Select '1' then ENTER
C2 – Select '1' then ENTER
C3 – Select '5' then ENTER
C4 – Enter '1000' KG
SCALE CALIBRATION
Open Menu – Press Hold and Print buttons at the same time
STEP 1 – Zero Calibration
Select C5 – Then select '1'
ENSURE NO WEIGHT ON THE PLATFORM – THEN PRESS ENTER
The indicator will auto countdown from 10 to 0 (CAL 10 to CAL 0)
Zero calibration is completed when the indicator displays 0.0
STEP 2 – Weight Calibration
Stand in the centre of the scale platform (know your exact weight)
Select C6 – Then Select '1' and then press ENTER (print button)
THEN ENTER THE EXACT WEIGHT ON PLATFORM IE '100' KG
THEN PRESS ENTER – LET THE COUNTDOWN RUN
WHEN CALEND IS DISPLAYED (CALIBRATION HAS COMPLETED)
STEP 3 – Animal Hold Function
C11 – Enter '4'
C12 – Select 3 or 5 second hold
Additional info - refer Page 15 in the enclosed weigh indicator operation manual
(SETS TO KG)
(ONE DECIMAL PLACE)
(GRADUATION)
(OR THE MAXIMUM WEIGHT YOU REQUIRE)
(ANIMAL HOLD FUNCTION)
(ANIMAL HOLD FUNCTION)