Replacing or regenerating the activated charcoal
filters
Activated charcoal filters trap the odour-causing
compounds in cooking smells. They are only used for
circulating-air mode.
Notes
The activated charcoal filters are included with the
appliance. When the activated charcoal filters need
to be replaced, they can be obtained from specialist
retailers, from our after-sales service or from our
online shop.
Only use genuine Bosch filters. This will ensure
that the appliance performs optimally.
Refer to the printed supplement for information
about the regenerability of the activated charcoal
filters.
1
Remove the holder on the rear of the metal grease
filter and take out the activated charcoal filter.
2
Clean the appliance.
3
Clean the metal grease filters.
4
Secure the new activated charcoal filter using the
holder on the rear of the metal grease filter.
Cleaning the metal mesh grease filters
Notes
Do not use any aggressive, acidic or alkaline
cleaning agents.
When cleaning the metal mesh grease filters, also
clean the holder for the metal mesh grease filters in
the appliance using a damp cloth.
The metal mesh grease filters can be cleaned in the
dishwasher or by hand.
By hand:
Note: You can use a special grease solvent for stubborn
dirt. It can be ordered via the Online Shop.
Soak the metal mesh grease filters in a hot soapy
solution.
Clean the filters with a brush and then rinse them
thoroughly.
Leave the metal mesh grease filters to drain.
10
In the dishwasher:
Note: If the metal mesh grease filters are cleaned in the
dishwasher, slight discolouration may occur. This has no
effect on the function of the metal mesh grease filters.
Do not clean heavily soiled metal mesh grease
filters together with utensils.
Place the metal mesh grease filters loosely in the
dishwasher. The metal mesh grease filters must not
be wedged in.
Installing the metal mesh grease filter
1
Insert metal grease filter.
2
Fold the metal grease filter up and click it into
place.
3
Fold the filter cover upwards.
Note: Make sure that the filter cover closes properly.
Resetting the saturation displays
Once you have cleaned or replaced the relevant filters,
reset the saturation indicator to stop the symbols from
flashing.
Make sure that the extractor hood and the lighting have
been switched off.
Press and hold the μ button for approximately
5 seconds.
This resets the saturation indicators.